Glow-worm F.29 fault codewhat it means and how to fix it
The flame was established and then lost, and re-ignition failed. Different from F.28 and it points somewhere else.
Take care
What F.29 means
F.29 is flame loss during operation, with the subsequent attempt to re-ignite also unsuccessful. Separating it from F.28 saves real time. On an F.28 the burner never lit; on an F.29 it did, ran, and then went out. That eliminates the ignition electrode as a primary suspect, because it evidently worked, and it eliminates a total absence of gas, because gas evidently arrived. What is left is a shorter and more specific list. Vaillant Group documentation for this code points at the gas supply being interrupted or at insufficient gas pressure, a fault in the flue gas route caused by recirculation or blockage, and poor electrical earthing. That last one is genuinely worth knowing about, because flame sensing works by passing a tiny current through the flame itself and depends on a sound earth to do so. A degraded earth produces intermittent flame loss that looks inexplicable until somebody tests it, and it is more common in older properties.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Gas supply interrupted or pressure insufficient | Enough to light and not enough to sustain. Characteristically worse when another gas appliance is drawing at the same time. | Common |
| Flue gas recirculation or blockage | Combustion products drawn back into the intake, or a partly obstructed flue. Degrades combustion progressively as the appliance warms. | Common |
| Poor electrical earthing | Named explicitly in the Vaillant Group documentation. Flame rectification depends on a good earth path, and a degraded one produces intermittent, baffling flame loss. | Occasional |
| Condensate backing up | A blocked trap or frozen drain flooding the chamber shortly after firing. Gives a consistent run time before dropout. | Occasional |
What to try yourself
Time how long the appliance runs before it drops out, over two or three attempts. Consistency points at condensate; variability points at gas supply or earthing.
Check whether it fails sooner with a gas hob running at full rate. If so, the supply is the likely limitation.
In cold weather, check the external condensate run for ice and thaw it with hand-hot water.
Mention the earthing possibility when you book. It is a listed cause, it is cheap to test, and it is very easily overlooked in favour of replacing parts.
Reset no more than twice and pass on your timing observations.
Get a Gas Safe registered engineer to look at your Glow-worm F.29
Gas Safe Register engineers only. No obligation.
What it costs to fix
Typical repair cost
£80–£450
Time on site
25 minutes
An earthing fault is often just a call-out charge of £80 to £150. Clearing a condensate blockage is £90 to £170. Gas supply corrections range from £200 to over £600.
Typical UK prices including parts and labour, updated August 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Condensate trap and siphon
COND-TRAP£15–£38Plumbing merchant
Price checked 5 August 2026
What other owners found
Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.
Related Glow-worm fault codes
- F.28Get it checkedIgnition was unsuccessful at start-up and the boiler has locked out. Check the gas and the condensate pipe before calling anyone.Related: ignition and gas supply
- F1Stop — call an engineerNo flame was detected during ignition, so the boiler has shut the gas off and locked out. Two resets at most before calling someone.Related: ignition and gas supply
- F.61Get it checkedA fault in the gas valve control circuit on the main board. The appliance will not fire and this needs an engineer.Related: ignition and gas supply
- EA 227Stop — call an engineerThe boiler tried to light and never detected a flame, so it has shut the gas off and locked out. This is the most common Worcester fault code.Related: ignition and gas supply
- E01Get it checkedThe appliance tried to light and could not confirm a flame, so it has locked out. In winter a frozen condensate pipe is the most likely reason.Related: ignition and gas supply
- F.28Stop — call an engineerThe boiler tried to light and failed three times in a row, so it has shut the gas off and locked out. Do not keep resetting it.Related: ignition and gas supply