Glow-worm F.29 fault codewhat it means and how to fix it

Get it checkedBoilerF.29 on Energy, Ultimate, Easicom, Betacom3/4 and Compact · F29 on Ultracom2, Betacom 24a/28a and Betacom2 · shown as F4 on Ultracom, Flexicom, Ultrapower and XtrafastLast updated

The burner lit and then the flame went out while running. Glow-worm blame the gas supply, flue gas recirculating, earthing, the spark transformer and, on newer manuals, a blocked condensate pipe.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

When does the flame go out?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

It lights, runs for a few minutes, then F.29

Recirculation, condensate or a weak flame signal — the burner is being starved or the sensing is marginal.

Check the terminal and condensate pipe from outside, then call an engineer if it repeats.

Only on windy days

Almost certainly the flue terminal position or condition.

Have the flue inspected. Glow-worm list this as recirculation and an engineer can assess terminal clearances.

At random, gas and flue look fine

Electrode, earth or transformer.

Book a Gas Safe registered engineer.

What F.29 means

F.29 is "Fault: Flame loss" in Glow-worm's tables, and the Compact manual spells out the difference from F.28: this is "ignition and check faults during operation — flame has gone out". The boiler got as far as a stable flame and then the ionisation signal disappeared, so it closed the gas valve and, after its retries, locked out.

Glow-worm's causes are shorter than for F.28 and more about the boiler's surroundings than its parts: "gas supply temporarily stopped, flue gas recirculation, incorrect earthing of product, ignition transformer has spark failure", with "condensate siphon blocked" added on the Energy7 and the Compact adding a blocked air/flue pipe and a disconnected reference pressure pipe. Flue gas recirculation deserves a sentence, because it is the cause a householder can sometimes see: if the flue terminal is boxed in, damaged, or too close to a wall or a neighbour's terminal, the boiler breathes its own exhaust, the oxygen falls, and the flame fails after a few minutes of running — a boiler that lights fine and dies later, in windy weather especially, is often this.

On the Ultracom2 and Betacom2 the same F29 is "loss of flame during operation"; on the Ultracom, Flexicom and Ultrapower the number is F4. Glow-worm's homeowner page gives F.29 the same householder checks as F.28 — other gas appliances, meter credit, ice in an outdoor condensate pipe — and adds one cause of its own, the control electrode touching the burner.

What causes it

Causes of the Glow-worm F.29 fault code, most common first
CauseWhat is actually happeningHow likely
Gas supply interrupted mid-runA prepayment meter running out while the heating is on, a supply pressure dip at peak time, or a gas cooker and boiler on an undersized run. Glow-worm's first listed cause on every range.Common
Flue gases being drawn back inGlow-worm call it flue gas recirculation. A terminal that is damaged, obstructed, guarded too closely or fitted where wind eddies push exhaust back to the air intake starves the burner after a good start.Common
Condensate backing upAdded to the F.29 causes on the Energy7 and Compact. A frozen or sludged discharge pipe lets condensate rise into the combustion chamber, and the flame drowns after running long enough to produce it.Occasional
Weak flame sensing or earthA worn electrode, a poor product earth or a failing ignition transformer produce a flame signal that flickers below the threshold, and the board reads a flame that is actually there as lost.Occasional

What to try yourself

  1. Confirm the gas is on and the meter in credit, exactly as for F.28. A flame that was lit proves gas was present a moment ago, so if the meter is fine this step is quick.

  2. Go outside and look at the flue terminal and the condensate pipe. A terminal with something leaning against it, a bird guard clogged with debris, or a plastic pipe with ice in it are all things Glow-worm list and all things you can fix without tools.

  3. Reset once the way your guide describes. If the boiler lights and then drops out again after a few minutes, do not keep going — that pattern is recirculation, condensate or a failing component, none of which improves with repetition.

    Do not remove a flue guard or alter the terminal. Anything beyond clearing loose debris from outside is a Gas Safe job.

Get a Gas Safe registered engineer to look at your Glow-worm F.29

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£0–£350

Time on site

20 minutes

Free if it was the meter or a blocked terminal. Electrode £90–£180. Flue repair or re-termination £150–£350.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Condensate trap and siphon

COND-TRAP£15–£38Plumbing merchant

Price checked 28 September 2026

Glow-worm ignition and flame-sensing electrode

£18–£45Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Common questions about Glow-worm F.29

Is F.29 more serious than F.28?

Not in itself — the boiler shut the gas off the instant the flame was lost, which is the protection working. The reason not to keep resetting is that each cycle repeats whatever is starving the burner.

Which Glow-worms show F4 instead?

The Ultracom cxi, hxi and sxi, Flexicom cx, hx and sx and Ultrapower sxi; the Xtrafast printed it as F04 "ignition fault — flame detection". Their user guides do not define F4 for the owner, so treat it as this page with a reset button on the fascia.

Could it be the gas valve?

Glow-worm do not list it against F.29, and the flame having lit argues against it. It appears against F.28 and F.68 instead.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?