Glow-worm F.73 fault codewhat it means and how to fix it

Get it checkedBoilerPressure sensor on Energy, Ultimate, Easicom, Betacom3/4, Compact, Ultracom2 and Betacom2 · pump not proving on Ultracom, Flexicom and UltrapowerLast updated

The water pressure sensor is reading too low to be real — open circuit or shorted — so the boiler has no pressure figure it trusts. On Ultracom boilers F73 is a pump fault instead.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F.73

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

Which display are you looking at?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

F.73 with a stop, or F73 on an Ultracom2 or Betacom2

Pressure sensor or its wiring. The pressure shown cannot be trusted until it is fixed.

Book a Gas Safe registered engineer. Do not keep topping up on the strength of the display.

F73 on an Ultracom, Flexicom or Ultrapower

Glow-worm's wording is "unable to see pump activate" — a circulation fault rather than a sensor fault.

Check the pressure reads at least 1.0 bar, reset once, and call an engineer if it returns.

What F.73 means

On the current ranges Glow-worm define F.73 as "water pressure sensor not connected or has short-circuited", and the Compact manual sharpens it to a sensor signal "in the wrong range (too low)". The boiler is not saying the pressure is low; it is saying it cannot believe the sensor, because the voltage coming back is one a working sensor never produces.

The causes Glow-worm list are all electrical: an interruption or short in the sensor itself, a short to earth in its supply line, or the sensor having failed internally. That is why topping up does nothing for this code, and why the display may show a pressure that is plainly wrong or 0.0. The Ultracom2 and Betacom2 manuals carry the same code as "heating circuit pressure sensor fault, the sensor is shorted or disconnected", so the two-digit boilers agree.

The Ultracom, Flexicom and Ultrapower do not: their F73 is "unable to see pump activate", the board having run the pump and seen no change in the pressure signal, so on those boilers the code is closer to what the current ranges call F.75. Either way this is an engineer's code — the sensor sits inside the casing on the hydraulic block, and the user guides for every range hand codes other than F.22, F.28 and F.83 to a competent person.

What causes it

Causes of the Glow-worm F.73 fault code, most common first
CauseWhat is actually happeningHow likely
Sensor cable unplugged, chafed or shorted to earthGlow-worm's wording is "interruption/short circuit of water pressure sensor, interruption/short circuit to GND in supply line". A plug disturbed during a service, or a cable rubbed through on the casing, is the cheap version of this fault.Common
Pressure sensor failed internallyThe sensor is a small transducer screwed into the hydraulic block, and its output drifting out of range is the other half of Glow-worm's cause list. Replaced as a unit, with the system drained down to the boiler.Common
Pump not proving pressure — Ultracom and Flexicom onlyOn the F1-to-F77 boilers F73 means the pump ran and the pressure signal did not move. A seized pump, an airlocked one or a sensor that cannot see it are the possibilities, and the older cause list for F9 overlaps.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£120–£240

Time on site

1 hour

Water pressure sensor replaced £120–£240 including the drain-down and refill. A wiring repair alone is at the bottom of that range.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Glow-worm water pressure sensor

£25–£60Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Glow-worm F.73

Can I top up to clear F.73?

Not on a current range. The code says the sensor cannot be read, not that pressure is low, so adding water changes nothing and risks overfilling a system you cannot see the pressure of.

How is F.73 different from F.74?

Same sensor, opposite direction. Glow-worm define F.73 as the signal too low or absent and F.74 as an electrical problem with the line shorted to 5 or 24 volts — the signal too high. Both are the sensor circuit.

Will the boiler run at all?

No. Without a pressure figure it will not fire, because the low-pressure protection depends on that sensor.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this