Glow-worm F.22 fault codewhat it means and how to fix it

Get it checkedBoilerF.22 on Energy, Ultimate, Easicom, Betacom3/4 and Compact · F22 on Ultracom2, Betacom 24a/28a, Betacom2, Ultracom, Flexicom and UltrapowerLast updated

Glow-worm's low-water-pressure shutdown, and the one code every Glow-worm user guide lets you clear yourself by topping the system up. The threshold differs by range.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

What does the pressure read, cold, with the code showing?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

Below 0.5 bar

Genuinely low. Top up as your guide describes and the code should clear.

Around 1 bar or more, and F.22 still shows

The boiler is being told there is no water when there is. That is the pressure sensor or the cable to it, both on Glow-worm's own cause list.

Book a Gas Safe registered engineer rather than topping up further.

This is the third top-up this year

Water is leaving somewhere. Look at the discharge pipe outside first, then ask for a leak check and an expansion vessel test.

Have the system inspected; repeated fresh water corrodes it from inside.

What F.22 means

F.22 — F22 on the older two-digit displays — is the boiler refusing to run a heat exchanger it believes is short of water. Glow-worm print it in every user guide as a fault the householder deals with, and they are more specific about the numbers than most manufacturers, which is worth having because the numbers change with the range. The Ultimate3 manual says the value flashes below 0.5 bar, the boiler stops below 0.3 bar and the display then reads 0.0 whatever the true pressure, so a refill appears to do nothing until it passes 0.3.

The Energy7 guide gives a working band of 0.5 to 2.7 bar rather than the Ultimate3's 1.0 to 1.5. The Ultracom2 guide flashes the pressure and stops the boiler below 0.4 bar and tells you to fill to between 0.8 and 1.2. The Flexicom guide, where F22 reads "low water pressure or ignition temperature rise too slow", says fill until 1.0 bar shows. And the Betacom2 guide gives no filling instruction at all for lack of water below 0.5 bar — it tells you to contact your installer.

On every range the installation manual adds two causes the gauge cannot show: a defective water pressure sensor, and a loose or damaged cable to the pump or to that sensor, which is why a boiler that shows F.22 at a healthy reading is a sensor job and not a filling one.

What causes it

Causes of the Glow-worm F.22 fault code, most common first
CauseWhat is actually happeningHow likely
Water has left the sealed systemGlow-worm's first listed cause on every range: "no or insufficient water in the product". A sealed system does not use water up, so a falling reading means a weep at a valve, a radiator tail, a buried joint or the safety discharge pipe outside.Common
Radiators bled and nobody topped upAir let out of radiators is volume taken out of the system, and the pressure falls with it. If anyone has had a bleed key out recently, this is the whole story and the fix is a top-up.Common
Expansion vessel lost its chargePressure that climbs high when hot and drops low when cold, with the discharge pipe dripping outside, is the vessel rather than a leak. Topping up treats the symptom for a week at a time.Occasional
Pressure sensor or its wiringThe installation manuals list "water pressure sensor defective" and a loose or defective cable to the pump or sensor. A reading that disagrees with a separate gauge, or F.22 at 1.2 bar, points here.Occasional

What to try yourself

  1. Read the pressure cold. On the Energy, Ultimate3 and Betacom4 it is on the display, and if the flow temperature is showing instead, the guides say to hold both temperature buttons together for more than five seconds to bring the pressure up. Older ranges show it on the display or a gauge under the casing.

  2. Find the filling arrangement your installer left. Glow-worm boilers have a filling loop or tap beneath the appliance; the Flexicom guide calls it the filling loop under the boiler with two taps, the Ultracom2 guide a filling tap located under the appliance.

  3. Fill slowly to the figure your own guide names: 1.0 bar on a Flexicom or Ultrapower, 0.8 to 1.2 on an Ultracom2, 1.0 to 1.5 on an Ultimate3 or Betacom4, anywhere in 0.5 to 2.7 on an Energy7 with 1.0 to 1.5 the sensible target. On an Ultimate3 the display sits at 0.0 until you pass 0.3 bar, so keep going.

    Close the taps and remove a loop hose when you finish — the Ultrapower guide says the flexible hose must be disconnected to comply with the water regulations, and a loop left open lets mains pressure into the heating.
  4. Press reset once if the code has not cleared by itself. If the fault persists after that, or if you are refilling more than once or twice a year, the guides all say the same thing: have the system checked for a leak.

Get a Gas Safe registered engineer to look at your Glow-worm F.22

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£0–£300

Time on site

10 minutes

Free to top up. Pressure sensor replaced £120–£220. Leak trace £90–£160. Expansion vessel recharge or replacement £80–£300.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Expansion vessel (8 litre, sealed system)

EV-8L£35–£85Plumbing merchant

Price checked 28 September 2026

Pressure relief valve, 3 bar

PRV-3B£18–£42Plumbing merchant

Price checked 28 September 2026

Glow-worm water pressure sensor

£25–£60Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Glow-worm F.22

Why does the Energy7 guide say 0.5 to 2.7 bar when the Ultimate3 guide says 1.0 to 1.5?

Because Glow-worm wrote them at different times for different boilers, and the Energy7 figure is the whole permitted band rather than a target. Aim for 1.0 to 1.5 bar cold on any of them; both guides agree that is comfortable.

The display shows 0.0 bar and the loop is open — is the filling loop broken?

On an Ultimate3, probably not. Glow-worm say the display shows 0.0 below 0.3 bar, so the number does not move for the first part of the fill. Give it a minute before deciding.

My Betacom2 guide tells me to call someone rather than fill it. Why?

That guide leaves the sealed system to a competent person and says so in its maintenance section. Other Glow-worm guides for the same period hand the filling to the owner. Follow the one written for your boiler if you want to stay inside its instructions.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.