Ideal H 1 fault codewhat it means and how to fix it

Get it checkedBoilerIsar HE, Icos HE, Mexico HE, Esprit HE, Esprit 2 and EliseLast updated

The control thermistor on the flow pipe of an Isar, Icos, Mexico HE or Esprit is reading wrongly. Ideal test its resistance and the wiring to the board, then replace the sensor or the PCB.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Ideal properly.

Get a Gas Safe registered engineer to look at your Ideal H 1

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What H 1 means

H 1 is Control Thermistor (Flow) Error on the LED display, the temporary code for the sensor the boiler steers by. It sits on the central heating flow pipe and tells the board how hot the water leaving the heat exchanger is; when its reading falls outside what the board will believe, the boiler shows H 1 and will not run properly until the reading comes back.

Ideal's chart removes the thermistor from the flow pipe, disconnects it and measures it — 9,700 to 10,300 ohms at 25°C, 2,400 to 2,600 at 60°C, 1,000 to 1,100 at 85°C — replacing it if the values are wrong; if they are right, the engineer checks continuity between the board and the sensor, repairs the wiring if there is none, and replaces the PCB if there is.

The same sensor on a Logic produces F4, and the same chart, but the consequences run further on the older boiler: Ideal's L A overheat frame sends the engineer to this thermistor when the flow passes 90°C before the overheat thermostat trips, because a control thermistor reading low is how an Isar comes to overheat in the first place.

What causes it

Causes of the Ideal H 1 fault code, most common first
CauseWhat is actually happeningHow likely
Thermistor out of toleranceIdeal's three-temperature test decides it. An NTC of this age that reads high at 25°C tells the board the water is cooler than it is.Common
Wiring or connector between sensor and boardThe continuity check in the chart. A corroded terminal on a sensor that has lived beside a hot pipe for fifteen years adds resistance the board reads as temperature.Occasional
PCB input failedCorrect resistance, good continuity, H 1 still showing: the last box in Ideal's chart is the board.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£380

Time on site

40 minutes

A thermistor £80–£150 fitted. Wiring repaired £70–£110. A replacement PCB, the last resort in Ideal's chart, £200–£380.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Ideal Logic flow or return thermistor (clip-on NTC)

£12–£35Authorised Ideal parts distributor

Price checked 28 September 2026

Ideal Logic primary PCB

£150–£320Authorised Ideal parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Ideal H 1

Can I keep using the boiler with H 1 showing?

It will not let you, or not for long. H 1 is temporary in the sense that it clears if the reading recovers, but a boiler that cannot trust its flow sensor does not fire normally, and Ideal give the householder nothing to try for it.

Is this why my Isar overheated?

Possibly. Ideal's overheat chart points the engineer at the control thermistor when the flow exceeds 90°C before the overheat thermostat trips. A sensor under-reading lets the boiler run hotter than it thinks it is, and the independent thermostat catches it as L A.

What is H 2, then?

The same test on the other sensor. H 2 is the control thermistor on the return pipe, on Isar models that have one; H 3 is the hot water thermistor on the plate heat exchanger. Each has its own page.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?