Vaillant F.2 fault codewhat it means and how to fix it

Get it checkedBoilerecoTEC plus ..6/5-5 storage combi and actoSTOR ("only in conjunction with F.91"), ecoTEC exclusive, 2005 ecoTEC combis as F.02; ecoTEC plus CS/1-5 as F.002. Not in the ecoTEC pro, ecoFIT, ecoTEC sustain, ecoMAX or turboMAX plus tables.Last updated

The hot water outlet sensor circuit is open. On a combi that is the sensor on the water leaving for your taps; on an ecoTEC plus storage combi it is the shift-load cylinder sensor.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Vaillant properly.

Get a Gas Safe registered engineer to look at your Vaillant F.2

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.2 means

F.2 is the open-circuit partner of F.12, and which sensor it refers to depends on the boiler. The 2005 ecoTEC servicing instructions print it as "domestic hot water outlet NTC open circuit (combination boiler only) — NTC connector not plugged in or loose, NTC defective, connector on the electronics not plugged in correctly, cable defective", which is the plain combi's outlet sensor.

The ecoTEC plus ..6/5-5 table reads "interruption: DHW outlet sensor — shift-load cylinder temperature sensor defective or not connected", to be checked "on the shift-load cylinder, only in conjunction with F.91", which ties it to the VUI storage combi and the actoSTOR module rather than a plain combi. The exclusive table carries the same row. The 2022 CS/1-5 returns to the simpler reading as F.002, "the signal for the domestic hot water connection temperature sensor has been interrupted", with the wiring harness and the sensor as its two causes.

In every version the board is reading nothing where it expects a temperature, so it cannot regulate hot water and stops producing it. The check list is the plug, the cable harness and the sensor, all inside the case, and the pro, ecoFIT, ecoTEC sustain and legacy tables do not carry the row at all.

What causes it

Causes of the Vaillant F.2 fault code, most common first
CauseWhat is actually happeningHow likely
Sensor plug not connected or looseVaillant's first cause in 2005 and still the first check. A connector disturbed during work on the plate heat exchanger or the pipework beside it.Common
Outlet or cylinder sensor failed openThe thermistor's element or lead has broken. A clip-on or immersion NTC, inexpensive as a part.Common
Cable harness breakA damaged lead between sensor and board. On the storage combi the run to the shift-load cylinder sensor is longer and more exposed than a combi's.Occasional
Board connector not seatedThe 2005 wording's "connector on the electronics not plugged in correctly". Checked before any part is ordered.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£170

Time on site

45 minutes

A reseated plug is a call-out of £80 to £120; a replacement sensor is £110 to £170 fitted.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Vaillant flow, return or cylinder temperature sensor (NTC)

£12–£38Authorised Vaillant parts distributor

Price checked 28 September 2026

Vaillant wiring harness (plug-and-cable set to a sensor or actuator)

£20–£65Authorised Vaillant parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?