Skip to content
FaultcodeCheck

Ideal F10 fault codewhat it means and how to fix it

Get it checkedBoilerLogic Combi2, System2, Heat2 and i-mini2 (2023 on)Last updated

The spark generator on a Logic Combi2 — the unit that makes the ignition spark — has failed a self-check. Ideal's instruction is to check its wiring and, if that is sound, replace it.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Ideal properly.

Get a Gas Safe registered engineer to look at your Ideal F10

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F10 means

F 10 is Spark Generator Fault, one of the codes the 2023 three-character Logic boards added so that an ignition problem could be pinned to a part rather than reported as a bare lockout. The spark generator is a small high-voltage transformer that turns the board's low-voltage command into the spark at the electrode; the electrode is the visible part at the burner, the generator is the box it is wired to.

Earlier Logic boards could only tell you the boiler had failed to light — L2 — and left the engineer to work through electrode, harness, generator and gas valve in Ideal's ignition chart. The Combi2 board monitors the generator circuit and calls out this fault on its own. Ideal's remedy is one line in the installation manual: check wiring, if OK replace spark generator. There is nothing in the user guide for it, and nothing a householder can usefully do beyond one press of Restart.

What causes it

Causes of the Ideal F10 fault code, most common first
CauseWhat is actually happeningHow likely
Generator wiring or connectorIdeal put the wiring first. The generator's supply lead and the HT lead to the electrode both live in a hot, vibrating space and a connector that has worked loose gives an intermittent fault.Common
Spark generator failedThe transformer has an open or shorted winding. Ideal's remedy after the wiring check is simply to replace it, and it is not an expensive part.Common
Board output faultNot in Ideal's one-line remedy for this code, but the same circuit appears in their ignition lockout chart, where a board that cannot drive the generator is the last thing checked.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£90–£200

Time on site

45 minutes

A spark generator fitted £90–£160; a little more if the electrode and lead are changed at the same time.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Ideal Logic ignition electrode

175565£18–£42Authorised Ideal parts distributor

Price checked 28 September 2026

Ideal Logic spark generator

£35–£80Authorised Ideal parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Ideal F10

Is this the same as an ignition lockout?

It is one specific cause of one. On a Combi2 you might see F 10 on its own, or L 02 after the boiler has tried to light without a working spark. Either way the engineer goes to the generator first, which is the point of the code.

Does an older Logic have this code?

No. The ESP1 and earlier boards report ignition failure as L2 and leave the diagnosis to the engineer's chart. F 10 belongs to the Logic Combi2, System2 and Heat2 and the i-mini2 from 2023.

Could I have smelled gas with this fault?

You should not have. The gas valve only opens once a spark is being generated and closes again within seconds if no flame is detected, so a dead spark generator means no gas rather than unburnt gas. If you can smell gas at all, that is a separate emergency: leave, and call 0800 111 999.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?