Ideal L6 fault codewhat it means and how to fix it

Stop — call an engineerBoilerLogic, Logic Max and Vogue Max rangesLast reviewed

A flame is being detected when there should not be one. Turn the appliance off and call a Gas Safe engineer rather than resetting it.

Get a Gas Safe registered engineer to look at your Ideal L6

Gas Safe Register engineers only. No obligation.

What L6 means

L6 is false flame detection on an Ideal appliance, and the L prefix tells you it is a lockout that will not clear on its own. The appliance is reading a flame signal at a point in the cycle when the gas valve should be closed and the burner out. Two things produce that. The likelier is current leakage on the electrode or a control board fault — in other words a sensing circuit reporting something that is not happening. The more serious is that the reading is accurate, gas is still burning after the valve was told to shut, and the gas valve is passing. That is a genuine gas safety fault rather than an inconvenience. Nothing you can observe from outside the casing will tell you which of the two you have, and the appliance cannot tell you either. The proportionate response is to assume the serious one until an engineer proves otherwise, which means isolating the appliance rather than resetting it.

What causes it

Causes of the Ideal L6 fault code, most common first
CauseWhat is actually happeningHow likely
Current leakage on the electrodeContamination, moisture, or a breakdown in the electrode lead creating a path that mimics a flame signal. The most common cause and the benign one.Common
Gas valve passingThe valve not sealing fully when closed. Less common, and the reason this code is treated urgently.Occasional
Damp inside the caseWater tracking across connectors after an internal leak, or condensation in an unheated garage installation.Occasional
Control board faultThe flame detection stage on the board misreading its own input. Diagnosed once the gas side is proved sound.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£110–£420

An electrode is £110 to £190 fitted. A gas valve is £280 to £420. Expect a diagnostic charge on top, because separating the two requires a flue gas analyser.

Typical UK prices including parts and labour, updated August 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Ideal Logic ignition electrode

175565£18–£42Authorised Ideal parts distributor

Price checked 5 August 2026

What other owners found

Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.

Common questions about Ideal L6

What should I do before I call anyone?

Cut the power at the fused spur and leave it cut — the L prefix is Ideal telling you they consider this a hard lockout rather than something the appliance should shrug off. Then find your guarantee paperwork. Ideal guarantees are among the longest in the trade, and calling an independent engineer while still covered can cost you the balance of it.

What should I tell the engineer?

Describe it as a false flame lockout and say the appliance is an Ideal showing L6. Ideal attribute this to current leakage on the electrode, so an engineer who knows the brand will know where to start rather than working through the possibilities on your time.

What does "current leakage on the electrode" actually mean?

Flame detection works by passing a tiny current through the flame itself. If moisture or carbon deposit gives that current an alternative path to earth, the appliance reads it as a flame even with the burner out. It is the electrical equivalent of a stuck sensor, and it is the benign end of the possibilities.

I kept resetting and now it shows LC instead. Have I made it worse?

You have not damaged anything — LC is just the reset counter tripping after five attempts in fifteen minutes. But it is the appliance making a fair point. Power off at the spur for a minute to clear LC, and then leave L6 alone until somebody has looked at it.

Written by

Fault Code Check editorial team

Updated

Reviewed by

Technical reviewer

Gas Safe registration to be displayed on appointment

Last reviewed

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Trade body guidance

Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.

Read our full verification process