Ideal F7 fault codewhat it means and how to fix it

Get it checkedBoilerEvery Logic generation, Independent, i-mini; Low Mains Voltage on Logic+, Logic Max and VogueLast updated

The mains voltage reaching the boiler has dropped below what the board will run on. Ideal's advice is an electrician or your electricity supplier, not a heating engineer.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Ideal properly.

What F7 means

F7 is Low Mains Voltage. The Logic's board monitors the supply and refuses to run the fan, pump and gas valve when the voltage sags, because low voltage makes the fan run slow, the gas valve chatter and the flame sensing unreliable — all things a boiler would rather not do with gas flowing. It is the only code in Ideal's user-guide table whose action is not the boiler at all: "Contact a qualified electrician or your electricity provider."

The Vogue manual gives the number the board is working to, less than 185 volts, and adds two follow-ups for the engineer — check whether a local generator is the supply, and if the mains measures fine, look at the pump and then the primary PCB, since a failing pump can drag the board's supply down from the inside. On a Combi2 the mirror-image code exists too: F 14 for a supply that is too high.

What causes it

Causes of the Ideal F7 fault code, most common first
CauseWhat is actually happeningHow likely
Poor supply into the propertyRural ends of long lines, shared supplies and evening peaks can all dip below 185 volts. Other appliances dimming or a flickering kettle light are the corroborating evidence.Common
A loose or corroded connection in the boiler's own circuitThe fused spur, its 3 amp fuse holder and the terminal block behind the boiler can all develop resistance that drops the voltage only under load.Common
Pump or PCB pulling the voltage downIdeal's Vogue chart sends the engineer to the pump, then the primary PCB, when the incoming mains measures correctly. The fault is inside the boiler but shows as a supply code.Occasional
Generator or inverter supplyIdeal single this out. A boiler run from a small generator during a power cut will frequently show F7 because the output droops the moment the pump starts.Rare

What to try yourself

  1. Check the rest of the house. Lights dimming when the kettle goes on, or an oven clock that keeps resetting, points at the supply rather than the boiler, and that is a call to your electricity network operator on 105.

  2. If everything else is normal, the fault is between the consumer unit and the board. Ideal's instruction is a qualified electrician; the fused spur and its connections are theirs to open, not yours.

Get a Gas Safe registered engineer to look at your Ideal F7

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£0–£300

Time on site

1 hour

Nothing if the network operator finds a supply fault, which they fix at no charge. An electrician's visit £80–£150; a pump or PCB if the fault is internal, £180–£300.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Central heating circulating pump

CH-PUMP-15-60£90–£180Plumbing merchant

Price checked 28 September 2026

Ideal Logic primary PCB

£150–£320Authorised Ideal parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Ideal F7

Should I call a heating engineer or an electrician?

Ideal say electrician or electricity provider, and that is the right first call because in most cases the boiler is reporting the house, not itself. The exception is when the supply measures fine at the spur: at that point the Vogue chart goes to the pump and PCB, and that is a heating engineer's job.

Will the boiler restart on its own when the voltage recovers?

F7 is an F code, so yes, it clears when the condition does. A boiler that shows F7 every evening at six and runs again at eight is describing your street's load curve, and the network operator will want to know.

What is the difference from F14?

Direction. F 14 on a Logic Combi2 is High Mains Voltage, with the same instruction to contact the electricity provider. Older Logic boards only report the low side.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?