Skip to content
FaultcodeCheck

Ideal F9 fault codewhat it means and how to fix it

Get it checkedBoilerLogic, Logic ESP1, Logic Combi2, Independent, i-mini; Spare PCB Not Set on Logic+ and Logic Max 2023Last updated

The control board has not been told what boiler it is in, or has failed. L9 is the same fault locked out. The 2011 Logic Combi row also covers a gas valve short circuit.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Ideal properly.

Get a Gas Safe registered engineer to look at your Ideal F9

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F9 means

Ideal call this Unconfigured PCB, and the name is literal. A Logic board leaves the factory blank and has to be told, at installation or after a replacement, whether it is in a combi or a system boiler, what gas it burns and what output size it is.

Until that is done it shows F9, and Ideal's ESP1 manual documents the sequence a new board goes through — uP on power-up, oF after Restart, then F9 until the installer dials in C for combi, n for natural gas and the boiler size with the central heating knob, pressing Restart after each. The manual puts in capitals that setting the correct size is critical for safe operation, because the board uses it to decide how hard to drive the fan and gas valve.

So F9 on a boiler that has just had work done means somebody did not finish the job; F9 on a boiler nobody has touched means the board has lost its configuration or failed. The 2011 Logic Combi guide widens the row to "unconfigured/faulty PCB or gas valve short circuit", and the Combi2 simply says PCB Fault, replace PCB.

What causes it

Causes of the Ideal F9 fault code, most common first
CauseWhat is actually happeningHow likely
New PCB fitted and not programmedThe most common route to F9 by far. The replacement board is working perfectly; it has not yet been told the type, gas and size, and will not run until it has.Common
Board has lost its stored configurationA brown-out or a board fault can wipe the settings. The boiler was fine yesterday and shows F9 today with nothing else changed.Occasional
PCB failureWhere configuration does not hold or cannot be entered, Ideal's chart ends at replacing the board.Occasional
Gas valve coil shortedOn the 2011 Logic Combi, Ideal include a gas valve short circuit in this row. The board sees a load it cannot make sense of and reports itself faulty.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£60–£380

Time on site

1 hour

Configuring a board that was left unprogrammed is a short visit, £60–£90. A replacement primary PCB fitted and configured is £250–£380.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Ideal Logic primary PCB

£150–£320Authorised Ideal parts distributor

Price checked 28 September 2026

Ideal Logic gas valve

£90–£200Authorised Ideal parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Ideal F9

Can I configure the board myself if the instructions are in the manual?

No. Ideal print the sequence in the installation manual, not the user guide, and they say in capitals that the size setting is critical to safe operation. Telling a 24 kW board it is a 35 kW boiler makes it run the gas valve for a burner it does not have. This is Gas Safe work.

Which Ideal boilers show F9?

Every Logic generation, the Independent, the i-mini and the Logic Code Combi. The ESP1 groups it as "F9 or L9 or F8 or L8 — PCB unconfigured or faulty". Logic+, Logic Max and Vogue show PCB Fault or Unconfigured PCB in words. On an old Isar or Icos, a board fault is L E or H E instead, and L9 there means an overheat, not a board.

The boiler was just serviced and now shows F9. Is that connected?

Very likely. If the PCB was changed during the visit and the configuration was not completed, or was entered wrongly, this is the code you get. Ring the engineer who did the work before paying anyone else.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?