Redring Heating after switch-offwhat to check

Stop — call an engineerElectric showerRedring Selectronic Premier and Selectronic Advanced, the electronically switched models, and the Glow Thermostatic, whose professional list has the same line with the remedy "Replace main logic PCB, which includes the triacs." Redring’s rotary-dial showers use a different power arrangement and the same symptom on those is a different fault.Last updated

A Selectronic that has been stopped with the Start/Stop button but can still be heard heating has lost control of its elements. Redring’s answer is a new triac board; yours is the isolator.

Get a qualified electrician to look at your Redring electric shower

We do not pass enquiries to a repair firm, so there is no form here. When you book a qualified electrician, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What this means

Redring put this in the Professional Service checklist, not the owner’s one, and the wording is precise: unit has been switched off using the Start/Stop button but can be heard heating the water. Their remedy is one line, replace triac PCB. Understanding why makes the severity obvious. The Selectronic controls its heating elements electronically, switching them through triacs on a power board rather than through the mechanical thermostat and pressure switch of a simple shower. A triac that has failed short stays conducting whether or not the logic board asks it to, so the element it feeds stays on.

With the shower stopped there is no flow, and an element heating standing water in a small heat exchanger is the condition every protection in the unit exists to catch: Redring’s outlet sensor should force an over-temperature shutdown, the two-stage mechanical cut-out above the heat exchanger should click the power off and, in the extreme, cut it permanently, and the pressure relief device should vent if the water flashes to steam. Those layers are why this fault usually ends in a tripped cut-out or a dripping PRD tube rather than anything worse. But they are the last line, not the plan, and an appliance relying on them every time it is switched off is not safe to keep using.

The sound is the clue: a faint hiss or a kettle-like ticking from the unit after it has stopped, sometimes with the casing warm to the touch and the display dark. This is not the cool-down. The Premier’s cool-down runs water and shows a scrolling display; the Advanced counts down from six to one; both are over inside a minute and both involve water flowing. Heating with the water stopped and the display off is the fault, and the one thing to do about it is to remove the power at the pull cord or wall isolator and leave it off until the board has been replaced.

What causes it

Causes of Redring Heating after switch-off, most common first
CauseWhat is actually happeningHow likely
Triac on the power board failed shortRedring’s named cause and remedy: replace the triac PCB. A shorted triac conducts regardless of the control signal, so its element stays live after Stop.Common
Element relay or power board faultThe same failure at a different point on the board, with the same result. Diagnosis is the engineer’s, with the power off and the cover removed.Occasional
Mistaken for the normal cool-downFor the first minute after Stop the shower runs water on purpose to cool the unit. Heating with no water and a dark display, after that, is the fault.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£120–£240

Time on site

2 minutes

A triac board and an electrician’s visit. On an older Selectronic Premier the board price is often weighed against a replacement shower.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions

What should I do right now?

Switch the shower off at the ceiling pull cord or the wall isolator and leave it off. If you cannot find one, switch off the shower circuit at the consumer unit, the largest breaker in the board. Then book an electrician; Redring’s remedy is a replacement triac board.

Will the safety cut-out protect me if I keep using it?

It has probably been doing so already, which is why the fault was noticed. Redring’s stage-two cut-out is one-shot and switches the shower off permanently when it operates, and the pressure relief device is single-use too. Neither is designed to be relied on daily.

How can I tell heating from the cool-down?

The cool-down has water flowing and a live display, a scrolling pattern on the Premier or a six-to-one countdown on the Advanced, and finishes within about a minute. Heating you can hear with the display dark and no water is the fault.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this