Triton Power on indicator not litwhat it means

Get it checkedElectric showerLast updated

The neon in the start/stop button is a direct test of whether the supply has reached the shower. Unlit with the cord on points outward, not inward.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a qualified electrician to look at the Triton properly.

What this means

Triton define this lamp with unusual precision and that definition turns it into a diagnostic tool rather than a decoration: when the electricity supply to the shower is switched on at the isolating switch, the neon in the start/stop button illuminates. Read carefully, that makes the neon a test of one specific thing — whether mains has physically arrived at the appliance. It is not reporting that the shower is healthy, that the elements work, or that anything internal is functioning. It is reporting the presence of a supply. That makes an unlit neon genuinely informative in a way that most indicator lamps are not.

With the pull cord on and the breaker on, a dark neon means the supply is not getting to the unit, and everything between the consumer unit and the shower becomes the subject: the breaker, the cable, the isolating switch and the terminals at either end. On a dedicated circuit with nothing else on it, that is a short list.

In practice the isolating switch dominates it. A ceiling pull cord is the only mechanical part in the chain, it is operated with a wet hand several times a day, and its contacts wear until they no longer make. The complement is equally useful: a neon that *is* lit with no water and no heat tells you the supply is fine and the fault is inside the appliance, which is a completely different and more expensive conversation. Using the lamp properly saves people from replacing showers that had a failed switch, which is one of the more annoying ways to spend money in this category.

What causes it

Causes of Triton Power on indicator not lit, most common first
CauseWhat is actually happeningHow likely
Isolating switch or pull cord failedThe only mechanical part in the supply chain and the one that wears out. Dominant cause on installations over about ten years old.Common
Breaker tripped or switched offCheck before anything else. Whether it tripped or was simply off changes the answer completely.Common
Loose terminal in the switch or at the showerA high-current connection that has worked loose. Frequently accompanied by discolouration, which makes it urgent rather than merely inconvenient.Occasional
Neon itself failedThe lamp is a component and it can fail while the shower works normally. Suspect it only when everything else behaves.Rare

What to try yourself

  1. Check the shower breaker at the consumer unit and note whether it tripped or was simply switched off. It is usually the largest in the board: Triton’s own table gives a 32 A MCB for 7.5 kW, 40 A for 8.5 and 9.5 kW and 45 A for 10.5 kW.

    If it trips again when the shower runs, stop resetting it and treat it as an electrical fault rather than a supply that needs restoring.
  2. Pull the cord and listen for a clean mechanical click. A soft or silent cord is a switch that has worn out and it is the commonest answer here.

  3. Look at the pull cord rose and the shower for browning or a hot-plastic smell. Any of that means leaving the circuit off and treating it as an overheating connection.

  4. Note whether the neon lights but the shower does nothing. That reverses the diagnosis — supply present, fault internal — and is worth telling whoever attends.

  5. If the breaker is sound and the cord clicks but the neon stays dark, the fault is in the run between them and needs testing rather than guessing.

Get a qualified electrician to look at your Triton electric shower

We do not pass enquiries to a repair firm, so there is no form here. When you book a qualified electrician, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What it costs to fix

Typical repair cost

£0–£140

Time on site

20 minutes

Nothing if the switch was off. A replacement pull-cord switch fitted is the common outcome; a fault inside the shower is a different order of cost.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions

What exactly does the neon prove?

That mains has arrived at the shower. Triton define it as lighting when the supply is switched on at the isolating switch — so it tests the supply chain rather than the health of the appliance.

The neon is lit but nothing happens when I press start. What now?

That is the useful opposite result. The supply is fine, so the fault is inside the unit — a solenoid, a switch or the electronics — rather than in the breaker, the cable or the pull cord.

Could the neon have failed on its own?

It can, and it is the reason a dark neon is not conclusive on its own. But it is well down the list: check the breaker and the pull cord first, because they fail far more often and cost far less to put right.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead