Charger keeps trippingwhat to check
Do not keep resetting it. UK chargepoints are required to detect a dangerous supply fault, and repeated tripping may be the charger reporting your electricity supply.
Stop — this needs an engineer
Get a registered electrician to look at your ev charger
We do not pass enquiries to a repair firm, so there is no form here. When you book a registered electrician, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.
What this means
A chargepoint that trips out and refuses to charge is often reporting something about the electricity coming into your house rather than about itself, and that is a distinction worth understanding before you reset it for the fourth evening running. UK wiring regulations require a chargepoint on the common type of domestic supply to protect against the loss of the combined protective earth and neutral conductor: BS 7671 regulation 722.411.4.1 offers a choice between an earth electrode and a device that detects the fault and disconnects, and the IET explain why it matters — if that conductor breaks, the metal body of the car can become live. Most manufacturers meet the requirement by building open-PEN detection into the unit rather than by installing an earth rod. Myenergi describe it as built-in protection against the loss of the protective neutral and earth conductor as required by BS 7671:2018 Amendment 1:2020, say in their installation manual that because it is built in there is no need to install an earth electrode, and describe what happens when it operates: the charger becomes completely isolated from the input supply, so that all conductors present at the output socket or cable, including protective earth and control signals, will be safe, removing any risk of potential electric shock. The commonest form of the detection is the one written into the regulation as option (iv): disconnect within five seconds if the voltage at the charging point, line to neutral, goes above 253 volts or below 207 volts.
Ohme publish exactly those numbers for their units, citing that clause, and they are useful because they explain the pattern. Their units disconnect the vehicle if the voltage is greater than 253 volts or less than 207 volts, the same window produces what their app records as overvoltage or undervoltage errors, and on the Home Pro the unit deliberately waits five minutes after the voltage recovers before reconnecting the car, so that a supply hovering around the threshold does not switch the vehicle on and off repeatedly. That is a measurement of your supply, not of your charger. Myenergi's zappi works to a slightly different published figure — more than twelve per cent from 230 volts for five seconds, resetting itself once the supply is back within ten per cent — but the principle is the same. Ohme's remedy is the most useful thing published in this category, because it sends you somewhere most owners would never think to call: your distribution network operator can test the voltage levels at your home and help adjust them, they should monitor over several days rather than take one reading because voltage fluctuates through the day and night, and once confirmed the operator will resolve it at your local substation.
Ohme even say to keep using the charger normally during the monitoring period. The network operators themselves publish the same route from their side: UK Power Networks say a charger that trips on voltage is a safety feature working, that you may need to switch it off and on at the isolator, that you should first have your installer or an electrician check your own equipment, and that if the problem persists they will send an engineer and, if necessary, fit a recording device for two weeks. The IET add a cause that is neither the network nor the charger: voltage drop along a long or undersized cable within your own installation can pull the voltage at the charging point below 207 volts under full load while the supply at the meter is fine, and that is an installer's measurement to make. So there are two quite different situations. If the trip is at the charger and clears on a reset, note when it happens and check the app for a voltage record. If the trip is the RCD or breaker in your consumer unit, and it happens more than once, stop resetting it and get an electrician.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Mains voltage outside the permitted window | Ohme publish 253 volts and 207 volts as the limits their units disconnect at. Voltage varies through the day and across a street, so this can be intermittent and time-of-day dependent. | Common |
| Open-PEN protection operating | The detection required on PME supplies. When it operates the charger isolates itself completely, which is the protection working rather than the charger failing. | Common |
| Earth leakage tripping the RCD | A genuine leakage fault in the charger, the cable or the vehicle. This is the case where repeated resetting is the wrong response and an electrician is the right one. | Occasional |
| The wrong type of RCD upstream | Ohme note that Type AC devices may saturate and fail to operate in the presence of smooth DC currents below 6 mA, and recommend any upstream RCD is at least Type A. An installation with the wrong device can behave unpredictably. | Occasional |
| A high-impedance or disconnected earth | Myenergi publish this as its own fault — the earth either disconnected or the impedance of the earth connection too high. It is an installation problem rather than an appliance one. | Occasional |
| Voltage drop on the charger’s own circuit | The IET’s point: a long or thin cable to the charger can drop the voltage at the charging point below 207 V under load while the meter reads normal, and the open-PEN device trips on a healthy supply. An installer measures it. | Occasional |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£0–£300
Time on site
45 minutes
Nothing if it is a supply voltage problem — that is your network operator’s to resolve at the substation. An electrician’s visit if the fault is in the installation, and a manufacturer call-out if it is the unit.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Own this appliance and had this code? . Nothing is published until a person has read it.
Related ev charger fault codes
- Not charging on scheduleUsually simple to fixAlmost certainly the law rather than a fault. Chargers are required to apply a random delay of up to ten minutes and to ship with a default off-peak schedule.Related: same brand
- Red lightGet it checkedDo not assume red means broken. Some manufacturers publish it as a stop condition; Ohme publish steady red on their Home and Go as connected and waiting for your car.Related: same brand
- Cable stuck in the socketGet it checkedAlarming and usually mechanical. The counterintuitive fix that manufacturers publish is to push the plug further in, not to pull harder.Related: same brand
- Charging slower than expectedUsually simple to fixUsually the charger sharing the house supply, a solar mode doing its job, or a CT clamp problem — Ohme publish a specific fallback to 16 amps.Related: same brand
Related guides
Common questions
Can I just reset it each time?
Once, to see whether it was a transient. Not repeatedly. These devices are protecting against a supply fault that can put dangerous voltage onto earthed metalwork, including a car parked on your drive with a cable plugged into it, and resetting past a protection device that keeps operating is the wrong response to it working.
Why would my electricity supply be the problem?
Because a chargepoint on a common UK domestic supply is required to watch the incoming voltage and disconnect if it goes outside a window. Ohme publish that window as 253 volts at the top and 207 at the bottom. Voltage in a street varies through the day and rises when several houses are exporting solar, so a charger can trip on conditions that have nothing to do with it.
Who do I actually call?
If the app shows overvoltage or undervoltage, your distribution network operator — Ohme publish that route explicitly and say the operator should monitor over several days because a single reading may miss it, and UK Power Networks ask you to have your installer or an electrician rule out your own equipment first. If the RCD or breaker in your consumer unit is what trips, an electrician. If neither, the charger manufacturer.
Is it safe to keep using in the meantime?
Ohme say to continue using the charger as usual during a network operator monitoring period, which tells you they consider the protection to be doing its job rather than failing. That is specific to the voltage case. If your consumer unit RCD is tripping repeatedly, leave it off and get it looked at.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
- Trade body guidance
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.