Baxi E.02.47 fault codewhat it means and how to fix it
"Connection to external device unsuccessful": a Baxi 200/400 Combi or Combi 2 has lost a control it was paired with. Check the control and its wiring; Baxi's remedy is the auto-detect function.
Before you start
What E.02.47 means
E.02.47 is the newer displays' version of the E83–E87 communication codes. The Combi 2 manual defines it as "connection to external device unsuccessful" with the cause "ELECTRICAL CONNECTION ERROR" and the remedy "possible cancellation, carry out the auto-detect function or re-enter the CN code"; the 200/400 Combi manual has the same description and "check wiring to external device", and pairs it with E02 48, "configuration to external device unsuccessful — check pairing to external, pair the devices". The external device is a Baxi room unit, a wired programmer on the boiler's bus, or an accessory board, and the boiler is reporting that something it was configured to talk to has stopped answering.
The Combi 2 has a family of A-codes for the same territory — A.02.36 and A.02.37 "functional device disconnected", A.02.45 "connection error", A.02.46 "device priority error", A.02.48 and A.02.49 — which are warnings the boiler runs through, and the manual's remedy for most of them is "carry out the auto-detect function", an installer menu that re-discovers what is connected. The permanent E.02.47 needs the RESET button, one second on a Combi 2 and at least three seconds on a 200/400, but the reset does nothing until the missing device is back or the boiler has been told to stop expecting it.
For the householder the useful checks are outside the boiler: the control's display and batteries, whether it has been unplugged or moved, and whether the code appeared the day a new thermostat was fitted. The last case is the common one, and the fix is in the installer's hands — either the pairing was not completed or a control was wired to the bus terminals that should have gone on the switched-live pair. The Combi 2 manual adds one line worth knowing: when a room unit or control unit is connected, "the code 254 is always shown in the event of a fault" on the control, and the real code is on the boiler's own display.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Control unpowered or removed | A room unit with flat batteries, a programmer off its backplate, or a control taken down and not refitted. The boiler expects it and cannot find it. | Common |
| Bus wiring | The 200/400 remedy "check wiring to external device". A two-core cable broken, loose at the boiler terminals, or reversed on a control that minds polarity. | Common |
| Pairing not completed | E02 48 on the 200/400, and the Combi 2's "carry out the auto-detect function". A new control fitted without the boiler being told about it, or an old one removed without the configuration being cleared. | Occasional |
| Accessory board fault | The Combi 2's A.02.36 and A.02.37 name a "SCB board not detected", an internal accessory board. "Check the connection and the connectors, faulty SCB, replace the board." | Rare |
What to try yourself
Check the room control: replace flat batteries, refit it to its wall plate, and see whether it shows a code of its own. On a Combi 2 the control may show 254; the real code is on the boiler.
If the code appeared after a new thermostat was installed, tell the installer. The pairing or the terminals are almost certainly the cause, and the boiler wiring cover is not for you to open.
Once the control is back, reset: one second on a Combi 2, at least three seconds on a 200 or 400 Combi. If E.02.47 stays, an engineer will run the auto-detect function or check the bus wiring.
Get a Gas Safe registered engineer to look at your Baxi E.02.47
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What it costs to fix
Typical repair cost
£0–£150
Time on site
15 minutes
Batteries or refitting a control cost nothing. Re-pairing or rewiring a control £80–£150. Accessory board £100–£200.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Baxi / Potterton / Main main PCB
£150–£320Authorised Baxi parts distributor
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Baxi fault codes
- E168Get it checkedTrade lists call E168 a Baxi PCB lockout, but no Baxi UK manual or error-code page prints it. Treat it as a board fault: one power cycle, then an engineer.Related: electronics and power
- E83Usually simple to fixE83 to E87: the boiler has lost contact with a connected control — a room unit or programmer wired to the board. Check the control first; the boiler itself is usually fine.Related: electronics and power
- E103Get it checkedSafety Assist codes E103, E104 and E107: the battery-backed safety board on the 600 and 800 is exhausted, faulty or out of step with the main board. Contact your installer; there is no reset.Related: electronics and power
- E55Get it checked"Calibration Required": the gas valve has not been set up to the board after a PCB or valve change. An engineer's combustion-analyser job, not a fault a householder can clear.Related: electronics and power
- E317Get it checkedMains frequency out of range (shown on some boards as 162). The boiler, not the supply, is almost always the odd one out. Check other appliances, then call an engineer.Related: electronics and power
- E385Get it checkedUnder-voltage (shown on some boards as 165): the supply at the board dropped below what it will run on. Usually a house-wiring or supply problem the boiler is reporting, not causing.Related: electronics and power
Own a Baxi boiler? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
- Manufacturer support portal
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.