Usually simple to fixBoilerDigital display, shown as E83, E84, E85, E86 or E87 with the spanner symbol: Baxi 600 and 800 Combi and System, Duo-tec 2 Combi GA, Duo-tec, Platinum and Megaflo Compact, Megaflo System, Assure, EcoBlue. Not in the selector-switch table. The Combi 2 uses A.02.45, A.02.47 and E.02.47 for external-device connection faults.Last updated

E83 to E87: the boiler has lost contact with a connected control — a room unit or programmer wired to the board. Check the control first; the boiler itself is usually fine.

Before you start

This one is usually safe to look at yourself. Do not remove any panel that is held on with screws or clips — everything below is done from the outside of the boiler.

What E83 means

Baxi print E83 through E87 as a single line — "Communication error" in the 600, 800, Compact and Duo-tec 2 tables and "E83 / E84 / E85 / E86 / E87 — No communication" on the professional page — and they mean the same thing: the board expected to hear from a device on its communication bus and did not.

On these boilers that device is a Baxi room controller or programmer wired to the two-wire bus terminals rather than to a simple switched-live input, and the five numbers distinguish which channel or which stage of the handshake failed, a detail the householder does not need because the remedy is the same for all of them. The boiler does not lock out for a communication error in the way it does for a flame or fan fault; it shows the code and, depending on the model and what it has lost, either carries on with its own settings or stops responding to demand until the control is back. Baxi give no reset for it. Neither the 600 user guide's reset list nor the installation manual's "possible to relight" list includes any of 83 to 87, and since the fault is a missing conversation rather than a stored lockout, the code clears itself when the control is found again.

The practical order is: the control's own display and batteries, if it has them; the two wires between control and boiler, especially where they enter the boiler's terminal strip; then the board. A boiler that was working with an old on/off thermostat and shows E83 after a new smart thermostat was fitted has almost always had the new control wired to the bus terminals when it should have been on the switched-live pair, or the other way round.

What causes it

Causes of the Baxi E83 fault code, most common first
CauseWhat is actually happeningHow likely
Control disconnected or unpoweredA wired room unit with a flat battery, a programmer unplugged from its backplate, or a control removed for decorating. The boiler reports no communication because there is nobody to talk to.Common
Bus wiringThe two-core cable between the control and the boiler's bus terminals broken, loose at the terminal strip, or reversed on a control that cares about polarity.Common
Wrong terminals after a new thermostatA third-party thermostat wired to the bus terminals, or a Baxi bus control wired to the switched-live terminals. The code appears the day the control is fitted.Occasional
Board communication circuitThe last suspect. The bus interface on the PCB has failed; ruled out by testing with a known-good control at the boiler terminals.Rare

What to try yourself

  1. Look at the room control. If it has a blank display or dead batteries, replace them; if it has been unplugged from a wall plate, refit it.

  2. If the code appeared right after a new thermostat was fitted, tell whoever fitted it — it is very likely on the wrong pair of terminals. Do not open the boiler's wiring cover yourself.

  3. Baxi give no reset for E83–E87 and none is needed; the code clears when the control is back in contact. If it stays, book an engineer to check the bus wiring at the boiler.

Get a Gas Safe registered engineer to look at your Baxi E83

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£0–£150

Time on site

15 minutes

Batteries or refitting a control cost nothing. Rewiring a control £80–£150. PCB, rarely, £250–£400.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Baxi / Potterton / Main main PCB

£150–£320Authorised Baxi parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?