Skip to content
FaultcodeCheck

Baxi E168 fault codewhat it means and how to fix it

Get it checkedBoilerReported on the three-digit digital-display Baxis (Duo-tec 2, Compact, 600, 800, Assure, Megaflo). Not printed in any Baxi UK fault table or on Baxi's error-code page; scoped here by where it is reported, not by a Baxi document.Last updated

Trade lists call E168 a Baxi PCB lockout, but no Baxi UK manual or error-code page prints it. Treat it as a board fault: one power cycle, then an engineer.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Baxi properly.

Get a Gas Safe registered engineer to look at your Baxi E168

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What E168 means

E168 is in an awkward position. It is widely quoted on merchants' and installers' lists of Baxi codes, usually as a PCB or general lockout, and this site had a page for it; but it is not printed in the fault table of any Baxi installation manual or user guide read for this site — the Duo-tec Combi HE A, Platinum, Platinum+, Duo-tec 2, 600, 800, Compact, Assure, Megaflo, EcoBlue — and it is not on Baxi's professional error-code page, which lists every code Baxi expect an engineer to meet on those ranges.

The manufacturer is silent on it. That does not mean the display cannot show it: Baxi's boards are shared across BDR Thermea and carry code definitions that the UK tables leave out, and the 600 Combi user guide anticipates exactly this — "if a different error code from those described in the table of error codes appears on the display contact Baxi Customer Support". So the honest position is that E168, where it appears, is one of those undocumented codes. The trade consensus that it is a board lockout is consistent with where it sits in the numbering, beside E160 (fan) and the electronics codes, and with what engineers report clearing it: a power cycle, a board, occasionally a wiring fault upstream of the board. This page therefore gives the safe advice for an unlisted electronics code rather than a manufacturer meaning.

Note the code exactly as displayed and the boiler model; switch the boiler off at the fused spur for a minute and on again, once; and if it returns, or comes with any smell of gas or sign of combustion trouble, stop and call a Gas Safe registered engineer or Baxi Customer Support with the code. It is not a code to reset repeatedly, because a board that is locking out for a reason it will not name may be protecting something that matters.

What causes it

Causes of the Baxi E168 fault code, most common first
CauseWhat is actually happeningHow likely
PCB internal fault (trade consensus, not Baxi's wording)The meaning installers and merchants give E168. A board that has failed a self-check or lost stored values. Confirmed only by an engineer, and only by elimination.Common
Supply disturbanceA brownout, a surge or a power cut mid-cycle leaves the board in a state it reports with an undocumented code. Clears with one power cycle and does not return.Common
Wiring or connector upstream of the boardA loose terminal or a chafed lead feeding the board intermittently. Found by an engineer checking the supply and connections before condemning the PCB.Occasional
A code from a non-UK tableThe boards are shared across BDR Thermea. The display may be showing a definition Baxi UK did not print, which is why the user guide says to contact Baxi Customer Support for any code not in the table.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£400

Time on site

45 minutes

Diagnosis £80–£150. PCB, if that is the conclusion, £250–£400 fitted.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Baxi / Potterton / Main main PCB

£150–£320Authorised Baxi parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Baxi boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer documentation checked — this code is not published in it, and we say so on the page

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?