Skip to content
FaultcodeCheck

Glow-worm F.64 fault codewhat it means and how to fix it

Get it checkedBoilerF.64 on Energy, Ultimate, Easicom, Betacom3/4 and Compact · F64 on Ultracom2, Betacom 24a/28a and Betacom2 · not in the Ultracom, Flexicom or CI tablesLast updated

F.64 is the board's analogue-to-digital converter reporting a reading it cannot make sense of — Glow-worm blame a shorted flow or return sensor first and the electronics second.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F.64

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.64 means

F.64 sits in the electronics block of Glow-worm's table but its first cause is a sensor. The Energy7 and Ultimate3 manuals give it as "Fault: electronics / sensor / analogue-to-digital converter" with the causes "flow or return NTC short circuited, electronics defective", and the Compact manual orders its measures the same way: check the flow temperature sensor, check the return temperature sensor, then the PCB.

The reason is that a thermistor shorted hard enough drives the converter's input beyond the range it can digitise, and the board reports the converter rather than the sensor that overloaded it. On the two-digit Ultracom2, Betacom 24a/28a and Betacom2 the code is F64, "rapid fluctuation of return or flow heating sensor", which describes the symptom from the other side — a reading jumping too fast to be real — and shares the F61-to-F67 measures of checking the board's connections, the board, the DSN and a reset. There is no equivalent in the Ultracom, Flexicom or CI tables.

An engineer meters both NTCs before condemning the board, because a thermistor is a small part and a board is not, and F.64 appearing alongside F.10 or F.11 in the fault history all but confirms the sensor. No Glow-worm user guide offers a householder step.

What causes it

Causes of the Glow-worm F.64 fault code, most common first
CauseWhat is actually happeningHow likely
Flow or return thermistor shortedGlow-worm's first cause. A hard short on either NTC overloads the converter input and the board raises F.64 instead of, or as well as, F.10 or F.11.Common
Harness short or water in a sensor plugThe same overload from the wiring rather than the sensor. A leak from the heat exchanger onto the sensor plugs below is the classic route.Occasional
Converter on the main board failed"Electronics defective." Confirmed only when both sensors and their wiring meter correctly; the board is then replaced and configured.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£380

Time on site

1 hour

A thermistor £80–£160 fitted if that is all it is. A main PCB £250–£380.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Glow-worm flow or return temperature sensor (clip-on NTC)

£12–£35Authorised Glow-worm parts distributor

Price checked 28 September 2026

Glow-worm main PCB

£150–£320Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?