Glow-worm F12 fault codewhat it means and how to fix it

Get it checkedBoilerDisplay-to-main-board connection on cxi, sxi, SI, CI, CI Plus, Xtramax HE and Xtrafast · cylinder sensor short on Energy7 system and regular boilers (with F.13 and F.91) and cylinder charging sensor short on the Energy 35 Store · not on Ultracom, Flexicom, Ultracom2 or BetacomLast updated

F12 on a cxi, sxi, CI or Xtramax is the link between the main board and the display board. F.12 on an Energy7 system boiler is a cylinder sensor short. Different generations, both engineer's codes.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F12

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

Which display are you looking at?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

F12 or 12 with a flashing red light on a cxi, sxi, SI, CI, CI Plus, Xtramax or Xtrafast

The connection between the display board and the main board, or one of the boards.

Book a Gas Safe registered engineer and mention any flickering or blank display beforehand.

F.12 with a full stop on an Energy7 system or regular boiler

Cylinder temperature sensor short circuit — the same fault as F.13.

Book a Gas Safe registered engineer for the cylinder thermistor and its cable.

What F12 means

On the Hepworth-era boilers — the cxi, sxi, SI, CI and CI Plus — Glow-worm's trade tables list F12 as "connection fault between main PCB and display PCB"; the Xtramax HE table has "user interface connection fault", the Xtrafast simply "user interface fault", and the 24CI/18SI manual gives 12 as "user interface or distant control panel fault". All of them describe the same thing: the ribbon or lead that carries the display board's conversation with the main board has stopped working, either because a plug has loosened, the lead has failed, or one of the two boards has.

The display may go blank, flicker, or show F12 alongside F11 and F18, which are the neighbouring codes for the same link and the interface itself. The Ultracom hxi, cxi and sxi and the Flexicom carry no F12; their board codes are F11 and F13. Nor do the two-digit Ultracom2 and Betacom boards.

On the current F.xx ranges the characters recur with an unrelated meaning: the Energy7 installation manual lists "F.12 and F.91 — short circuit: cylinder temperature sensor" beside F.13, which applies only to a system or regular boiler wired to a hot water cylinder, and the Energy 35 Store manual has F.12 as "cylinder charging sensor short circuit" on its built-in store; both are covered on the F.13 page. So a reader has to know which display they are looking at — a two-digit number with a flashing red light on a boiler from the early 2000s, or F.12 with a full stop on a recent system boiler — before either explanation applies. Neither generation gives the householder a step.

What causes it

Causes of the Glow-worm F12 fault code, most common first
CauseWhat is actually happeningHow likely
Display-to-main-board lead or plug — cxi, sxi, SI, CI, XtramaxGlow-worm's "connection fault between main PCB and display PCB". The lead runs through the hinged fascia and its plugs work loose over years of the panel being opened; the 24CI manual has the fascia unclipped and hinged forward for every board job.Common
Display board or main board failedIf the lead and plugs prove good the fault is in one of the boards at either end. The engineer proves the cheaper display board first.Occasional
Cylinder sensor short — Energy7 system and regular boilersThe current-range meaning. "NTC sensor defective, short circuit in the cable harness"; the cylinder thermistor and its long cable are metered and the failed part replaced. See the F.13 page.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£300

Time on site

1 hour

A lead reseated or replaced £80–£150. A display or main board on an older range £200–£300 where still available. A cylinder thermistor on an Energy7 £80–£160.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Glow-worm flow or return temperature sensor (clip-on NTC)

£12–£35Authorised Glow-worm parts distributor

Price checked 28 September 2026

Glow-worm main PCB

£150–£320Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer support portal
  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process