Glow-worm F15 fault codewhat it means and how to fix it

Get it checkedBoilereBUS voltage on Ultracom cxi/hxi/sxi, Flexicom cx/hx/sx and Ultrapower · gas valve stepper motor on cxi, sxi, SI, CI and CI Plus, "gas mechanism fault" on Xtrafast · not under this number on Ultracom2, Betacom or the F.xx rangesLast updated

F15 is the eBUS voltage on an Ultracom, Flexicom or Ultrapower, and the gas valve stepper motor on a cxi, CI or CI Plus. Know which boiler you have before anyone orders a part.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F15

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

Which boiler do you have?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

An Ultracom, Flexicom or Ultrapower — reset button on the fascia

eBUS voltage failure — the wiring to your controls.

If a control has just been fitted or changed, tell whoever did it first; otherwise book a Gas Safe registered engineer.

A cxi, sxi, SI, CI, CI Plus or Xtrafast — reset from the On/Off switch

Gas valve stepper motor fault. A gas fault.

Do not reset repeatedly. Book a Gas Safe registered engineer.

What F15 means

F15 is the clearest example of Glow-worm's two older code lists colliding. On the Ultracom cxi, hxi and sxi, the Flexicom cx, hx and sx and the Ultrapower, the trade tables give F15 as "E-bus voltage failure" — the two-wire link to compatible controls has lost its voltage, the fault the current ranges call F.49, and one that almost always traces to a control wired wrongly or a cable damaged.

On the earlier cxi, sxi, SI, CI and CI Plus the same F15 is "gas valve stepper motor fault", the 24CI/18SI manual lists 15 as "stepper motor fault (gas valve)", and the Xtrafast table has "gas mechanism fault" — the motor that positions the gas valve has failed or lost its connection, a gas fault with no user-side answer. A control wiring problem and a gas valve motor have nothing in common except the two digits on the display, and the cost of confusing them is a gas valve quoted for a boiler that needs a thermostat rewired, or the reverse.

The boiler tells you which list applies: the Ultracom, Flexicom and Ultrapower are named on the casing, date from about 2006 onward and have a reset button; the cxi, CI and CI Plus are early-2000s boilers reset from the On/Off switch. Neither meaning appears under F15 on the two-digit Ultracom2 and Betacom boards or on the current F.xx ranges. Glow-worm give the householder nothing to do for either.

What causes it

Causes of the Glow-worm F15 fault code, most common first
CauseWhat is actually happeningHow likely
eBUS wiring — Ultracom, Flexicom, Ultrapower"E-bus voltage failure." A control connected with reversed polarity, a cable nicked or pinched, or too many devices on the bus. Follows a change to the controls more often than not.Common
Gas valve stepper motor — cxi, sxi, SI, CI, CI Plus"Stepper motor fault (gas valve)." The motor that drives the valve, or its plug and lead. The valve is replaced as an assembly where the motor has failed.Common
Board driving eitherOn both lists the main board supplies the eBUS or drives the stepper, and a board fault gives the same code. Reached only when the wiring or the valve proves good.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£320

Time on site

1 hour

A controls wiring correction £80–£130. A gas valve assembly on a CI-era boiler £250–£320 fitted, where still available.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Glow-worm gas valve assembly

£90–£200Authorised Glow-worm parts distributor

Price checked 28 September 2026

Glow-worm main PCB

£150–£320Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer support portal
  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?