Glow-worm F.77 fault codewhat it means and how to fix it

Get it checkedBoilerFlue non-return flap or condensate pump on Energy, Ultimate, Easicom, Betacom3/4 and Compact · gas valve motor or condensate pump on Ultracom2, Betacom 24a/28a and Betacom2 · condensate pump on Ultracom hxi and FlexicomLast updated

F.77 on current ranges is the flue non-return flap or condensate pump not answering. On a Betacom2 or Ultracom2 it is the gas valve motor; on an Ultracom or Flexicom the optional condensate pump.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F.77

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

Which display are you looking at?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

F.77 with a stop

Flue non-return flap or condensate pump not responding.

Book a Gas Safe registered engineer. Tell them whether a condensate pump is fitted.

F77 on an Ultracom2, Betacom 24a/28a or Betacom2

Glow-worm's "fault in gas valve motor", or the optional condensate pump.

Book a Gas Safe registered engineer. This is a gas valve check; do not reset repeatedly.

F77 on an Ultracom hxi or a Flexicom

"Condensate pump error (optional)" — the pump, its float or its wiring.

If you can see the pump is full or its pipe is kinked, say so when you book the engineer.

What F.77 means

Three generations give F77 three meanings. On the Energy, Ultimate and Easicom it is "Fault: condensate or smoke — no response, flue non-return flap defective": where a boiler shares a flue with others, a non-return flap stops flue gas from another appliance being pushed back, and the board expects the flap to report its position. The Compact manual widens the title to "flue non-return flap/condensate pump" and adds "condensate pump defective — replace the condensate pump", because a condensate pump's alarm contact can be wired to the same input.

On the two-digit Ultracom2, Betacom 24a/28a and Betacom2, F77 is "fault in gas valve motor — defective gas valve, defective condensate pump (option)", and the measures are to check the gas valve connections and operation and, if fitted, the condensate pump. On the older Ultracom hxi and Flexicom the trade table has F77 as "condensate pump error (optional)", full stop. So a homeowner with a Betacom2 who reads the current manual's explanation will be told about a flue flap their boiler does not have.

In every version the common thread is an external device the board is waiting to hear from, and in every version Glow-worm give the householder nothing to do. The one useful observation an owner can make is whether a condensate pump is fitted at all — a small box under or beside the boiler with a pipe running uphill from it — because if there is one, its float or its wiring is the first place the engineer will look.

What causes it

Causes of the Glow-worm F.77 fault code, most common first
CauseWhat is actually happeningHow likely
Condensate pump alarm — any range with a pump fittedA condensate pump has a float switch that signals when it cannot keep up. Glow-worm name it on the Compact, the two-digit boards and the older Ultracom and Flexicom. A pump full of sludge or with a kinked discharge pipe trips the alarm and the boiler stops.Common
Flue non-return flap not answering — Energy, Ultimate, Easicom, Compact"No response, flue non-return flap defective." On a shared flue installation the flap's feedback contact has failed or its wiring has broken. On a boiler with its own flue and no flap, a board configured to expect one gives the same code.Occasional
Gas valve motor — Ultracom2, Betacom 24a/28a, Betacom2Glow-worm's first cause on the two-digit boards is the gas valve, not the flue. The measures are to check its connections and its operation. A gas valve is a gas-carrying part and no owner should touch it.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£320

Time on site

1 hour

A condensate pump cleared or its float freed £80–£130; replaced £150–£250. A flue flap or its wiring £100–£200. A gas valve on a two-digit board £250–£320.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Glow-worm gas valve assembly

£90–£200Authorised Glow-worm parts distributor

Price checked 28 September 2026

Glow-worm main PCB

£150–£320Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?