Skip to content
FaultcodeCheck

Ideal uP fault codewhat it means and how to fix it

Get it checkedBoilerLogic ESP1 and related two-character Logic boardsLast updated

A new or reset control board waiting to be programmed. Ideal's manual shows uP as the first thing a replacement PCB displays, before F9, until the installer tells it what boiler it is in.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Ideal properly.

Get a Gas Safe registered engineer to look at your Ideal uP

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What uP means

uP is not in any fault table, but people see it and search for it, and Ideal document exactly what it is. In the PCB replacement procedure for the Logic ESP1, step ten reads: turn power on, display shows uP; rotate all three dials fully anticlockwise; press Restart, display shows oF; turn power off; turn power on, display shows F9. From there the installer uses the central heating knob to dial in C for combi, n for natural gas and the boiler size, pressing Restart after each, until the display shows the configuration and one final Restart programmes the board.

So a boiler showing uP is at the very start of that sequence — a board that has never been configured, or one that has lost its configuration and reverted. It will not heat anything in this state. If you are seeing it on a boiler that has just had a PCB fitted, the job was not finished; if you are seeing it on a boiler nobody has touched, the board has failed in a way that wiped it.

What causes it

Causes of the Ideal uP fault code, most common first
CauseWhat is actually happeningHow likely
Replacement PCB fitted and not programmedThe engineer fitted the board, saw the display light up and left, or was interrupted before the dial-in sequence. This is where Ideal's own procedure says a new board starts.Common
Board reverted to factory stateA PCB whose stored configuration has been lost behaves like a new one. It is uncommon, and the board is usually replaced rather than reprogrammed because whatever wiped it will do so again.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£60–£380

Time on site

30 minutes

Finishing an unprogrammed board is a short visit, £60–£90, and arguably the original engineer's to make at no charge. A failed board replaced and programmed £250–£380.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Ideal Logic primary PCB

£150–£320Authorised Ideal parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Ideal uP

The manual prints the programming steps. Why can I not do them?

Because the steps include telling the board the boiler's gas type and output, and Ideal print in capitals that setting the correct size is critical to safe operation. The board sets the gas rate from it. This is Gas Safe work and the installation manual is written for the engineer, not the householder.

Is uP the same as F9?

They are stages of the same condition. uP is the board before configuration begins; F9 is what it shows part-way through, and what it shows if configuration is abandoned there. Both mean the PCB does not yet know what it is driving.

What is oF?

The step after uP in Ideal's sequence: with all three dials turned fully anticlockwise, pressing Restart shows oF, and the board is then powered off and on to reach F9. You would only see it during programming.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process