Vokèra A09 fault codewhat it means and how to fix it
The flue gas sensor has recorded a temperature above the safe limit, or the sensor itself has failed. Either way the appliance stops.
Take care
Get a Gas Safe registered engineer to look at your Vokèra A09
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What A09 means
A condensing boiler should send comparatively cool gas up the flue, because extracting that heat into the water is the entire basis of its efficiency. A09 means the flue thermistor has either measured a temperature well outside normal, or has failed in a way the board can detect.
Where the reading is genuine, the cause is nearly always that heat is not transferring properly into the water — scale or sludge lining the heat exchanger, or circulation too slow to carry heat away — so it leaves through the flue instead. Vokèra split the code into two rows, and which one you have matters. A flue thermistor fault, or a fault with what they call the flue thermistor counter, is classified as temporary and will clear itself. A flue thermistor over temperature is Final: it stops the appliance until somebody resets it.
The reason the second one is treated that way is the flue itself, because plastic flue systems are rated for the temperatures a condensing appliance normally produces and sustained overtemperature is what they are not designed to handle. What the counter actually counts is not something Vokèra explain in the manuals we could reach; their instruction to the engineer is to check it at power on.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Heat exchanger scaled or fouled | A deposit layer insulates the metal from the water. Progressive over months, and common in hard water areas or on systems with no inhibitor. | Common |
| Poor circulation | Slow-moving water absorbs less heat per pass, pushing more of it out through the flue. Shares most of its causes with the overheat fault. | Common |
| Flue thermistor failed | The sensor is reporting a temperature that is not real, or has gone open circuit. Straightforward and inexpensive once identified. | Occasional |
| Appliance overfiring | Gas rate set too high, usually after a previous repair. Confirmed with a flue gas analyser rather than by eye. | Rare |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£140–£1,100
A flue thermistor is £140 to £220 fitted. A chemical clean with a magnetic filter is £400 to £750. A heat exchanger replacement runs £700 to £1,100, at which point a new appliance is often the better value.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Magnetic system filter, 22mm
MAG-22£65–£120Plumbing merchant
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Vokèra fault codes
- A03Get it checkedThe appliance cannot confirm the fan is running correctly, so it will not permit the burner to light. This needs an engineer.Related: fan and flue
- A01Get it checkedThe burner failed to light and the appliance has locked out. Check the gas supply and, in cold weather, the condensate pipe before calling anyone.Related: same brand
- A04Usually simple to fixSystem water pressure is below the minimum the appliance will run at. Topping the system back up to 1.2 bar normally clears it straight away.Related: same brand
- A02Get it checkedThe safety limit thermostat has tripped on overheat. In practice this nearly always means water has stopped circulating properly.Related: same brand
- A11Stop — call an engineerThe appliance is detecting a flame when there should not be one. Turn it off at the fused spur and get a Gas Safe engineer out.Related: same brand
- A07Get it checkedThe primary flow sensor is reading out of range or has failed. The appliance stops because it can no longer tell how hot it is running.Related: same brand
Own a Vokèra boiler? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.