Burning smell from the shower or pull cordwhat to check

Stop — call an engineerElectric showerLast updated

Hot plastic, scorching or discoloured fittings on a shower circuit is an overheating connection. Switch the circuit off at the consumer unit and leave it off.

Get a qualified electrician to look at your electric shower

We do not pass enquiries to a repair firm, so there is no form here. When you book a qualified electrician, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What this means

This is the fault on an electric shower that is about fire rather than about showering, and it is worth being plain about why it is treated more seriously than anything else in the category. An electric shower is the largest single-appliance load in a normal house. A 9.5 kW unit draws around 40 amps continuously while it runs, which is more than a cooker, more than an immersion heater and roughly what the rest of the house uses put together. Everything in that chain — the cable, the terminals in the isolating switch, the terminal block in the shower — is sized for that current on the assumption that every connection is tight.

When one is not, the resistance at that point turns into heat, the heat degrades the plastic and the metal around it, and the joint gets worse rather than better because a hotter connection is a higher-resistance one. That is a runaway, and the smell is the middle of it rather than the beginning.

There are two places it usually happens and both are reachable. The ceiling pull cord is one, because it is the only mechanical switch in the run and its terminals are small for the job they do. The shower’s own terminal block is the other, particularly on a unit that has been swapped at some point and reconnected. The reason there are no steps on this page is not caution for its own sake: the diagnosis requires the cover off a live circuit or a proper isolation and test, and the failure mode while you are working out which it is happens to be fire.

What causes it

Causes of Burning smell from the shower or pull cord, most common first
CauseWhat is actually happeningHow likely
Loose terminal at the isolating switchThe pull cord carries the full load through small terminals. One that has worked loose heats every time the shower runs and browns the plastic around it.Common
Loose or corroded connection at the showerThe terminal block inside the unit, often disturbed when a shower was last replaced. Damp in the room accelerates it.Common
Cable undersized for the shower fittedA higher-kW unit put on the cable that fed a smaller one. The whole run warms rather than one joint, and it will smell warm rather than scorched.Occasional
Element or internal component failingA failing element can smell hot before it fails outright. Less common than a connection but it presents the same way from outside.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£300

Time on site

1 hour

Remaking a connection or replacing a pull-cord switch is at the low end. A cable that turns out to be undersized for the shower on it means running a new circuit, which is the expensive outcome and is notifiable work.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions

It only smells while the shower is running. Is it still urgent?

Yes, and that pattern is the giveaway rather than a reassurance. A connection that only heats under load is exactly what a loose high-current terminal does, and load is when the risk exists.

The shower still works fine. Do I have to stop using it?

Yes. A shower that works is not evidence that the connection is sound — the joint carries current right up until it fails, and it degrades every time you run it. Switch the circuit off at the consumer unit and leave it off.

What will an electrician actually do?

Isolate the circuit, open the switch and the shower, and look at the terminals. A browned or pitted connection is visible immediately. Remaking it, or replacing the switch, is usually a short job once the cause is in front of them.

Could it be the shower rather than the wiring?

It can be, and that is part of what the visit establishes. But the connections are checked first because they are the commonest cause and because they are the ones that get worse on their own.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?