Shower keeps tripping the electricswhat to check

Stop — call an engineerElectric showerLast updated

A shower that trips the breaker or RCD is reporting a real electrical fault. Do not keep resetting it to get one more shower out of it.

Get a qualified electrician to look at your electric shower

We do not pass enquiries to a repair firm, so there is no form here. When you book a qualified electrician, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What this means

This is the one fault in the category where the appliance is telling you something about safety rather than about performance, and where the instinctive response makes it worse. An electric shower sits on a dedicated high-current circuit, protected by a breaker against overload and, because it is in a bathroom, by a 30 mA residual current device against current leaking to earth. Those two devices trip for different reasons and which one has moved tells you a great deal. A breaker alone usually means current above what the circuit is rated for.

An RCD means current is going somewhere other than back down the neutral, and in a shower there is one overwhelmingly common route for that: the heating element sits in water, and when its sheath fails the element starts leaking to earth through the water itself. The reason this is rated the way it is has nothing to do with the inconvenience. An RCD that trips is a device doing exactly what it was fitted to do, on a circuit that is in a wet room, feeding an appliance you stand inside while wet and barefoot.

Resetting it repeatedly to force one more shower is asking a safety device to keep catching a fault that is still there, and the failure mode people do not expect is that the leakage gets worse gradually rather than suddenly. There is a second cause worth naming because it is not the shower at all: water tracking into the pull cord or the isolator. Both live in a humid room, both have terminals in them, and either will trip an RCD in a way that looks identical from the consumer unit.

What causes it

Causes of Shower keeps tripping the electrics, most common first
CauseWhat is actually happeningHow likely
Heating element leaking to earthThe commonest cause. The element sheath fails, water reaches the conductor, and current finds a path to earth that the RCD sees immediately.Common
Moisture in the pull cord or isolator switchSteam gets into the switch, condenses across the terminals and leaks to earth. The shower itself is fine and the trip looks exactly the same.Occasional
Water inside the shower casingA failed internal seal or a split hose tail wets the electronics. Often accompanied by a shower that has also started dripping from underneath.Occasional
Circuit not rated for the appliance on itA higher-kW shower fitted to the cable and breaker sized for the old one. This trips under load rather than at switch-on, and it is a wiring fault rather than a shower fault.Occasional
Loose or overheated terminalA connection that has worked loose on a 40 amp circuit heats up under load. This is the version that leaves scorch marks and a smell.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£260

Time on site

1 hour

An electrician’s visit to find which side of the isolator the fault is on, plus the element or the switch. If the circuit turns out to be undersized for the shower on it, that is a rewire of the run and a different order of cost.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions

It only trips when the shower is running. Does that narrow it down?

Yes, considerably. A fault that only appears under load points at the element or at the terminals carrying the current to it, rather than at the standing wiring. It does not make it less urgent — it is the load that makes it dangerous.

Can I just reset it and shower quickly?

No. The RCD is what stands between a fault to earth and the person standing in the water, and it has already told you the fault exists. Leave the circuit off and get it looked at.

How do I tell whether it is the shower or the switch?

You mostly cannot from outside, and that is the point of the visit. An electrician can isolate the shower from the circuit and test each part in a few minutes, which is a much smaller job than it sounds.

Everything else in the house trips too. Is that different?

It usually means one RCD is protecting several circuits and the shower is the one with the fault. It is the same fault, just wired so that it takes the lights with it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this