Mira I fault codewhat it means and how to fix it
Flashing red and white with Start/Stop flashing. Mira call it a software error, and their published remedy is simply to power cycle the unit.
Take care
What I means
Code I is Mira’s catch-all for the control software getting into a state it cannot get out of, and the remedy they publish is the shortest in the table: power cycle the unit. That is worth taking at face value rather than treating as a brush-off, because it tells you what kind of fault this is. A software error in this context is not a corrupted program — it is the controller finding itself in a condition its logic does not have a route out of, typically after an interruption at an awkward moment, a supply glitch, or a sensor reading arriving out of sequence.
Removing the supply for long enough that the electronics genuinely lose state, and then restoring it, puts the controller back at a known starting point. Which is why the detail that matters here is how long you leave it off. A second at the pull cord is not a power cycle; the capacitors on the board hold enough charge to keep the controller alive through a brief interruption, and the fault comes straight back because nothing was actually reset. Ten to fifteen seconds off is the practical minimum. The other thing to take from this code is what to do if it recurs. A software error that appears once after a power cut and never returns is exactly what the code is for.
One that comes back every few days is not a software problem in any useful sense — something is putting the controller into that state repeatedly, and the candidates are a marginal supply, a sensor reporting intermittently, or a board that is failing. At that point the power cycle stops being a remedy and becomes a way of postponing a diagnosis.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Controller left in an unrecoverable state | The published cause. Usually follows an interruption at an awkward point in the cycle rather than anything physically wrong. | Common |
| Supply glitch or brief power interruption | A dip or a momentary outage that is long enough to disturb the controller and too short to reset it cleanly. | Occasional |
| Sensor reporting intermittently | A loose connector or a marginal thermistor producing readings the logic was not written to expect. This is the version that recurs. | Occasional |
| Control board beginning to fail | Where a repeatedly recurring software error usually ends up. Not diagnosable from outside and not an owner repair. | Rare |
What to try yourself
Switch the shower off at the pull cord or isolator and leave it off for at least fifteen seconds. A brief flick is not long enough to reset the controller.
Switch back on and start the shower. Watch the lights during start-up — if a different indication appears, that is the real fault and this code was masking it.
Run it for five minutes at showering temperature, which is Mira’s own confirmation check, rather than judging it on whether it started.
Keep a note of when it happens if it recurs. A pattern — always after a power cut, always at start-up, always cold — is what turns this into a diagnosable fault.
If it returns within days, stop power cycling it and have it looked at. A recurring software error is a symptom of something else rather than a thing in itself.
Get a qualified electrician to look at your Mira I
We do not pass enquiries to a repair firm, so there is no form here. When you book a qualified electrician, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.
What it costs to fix
Typical repair cost
£0–£200
Time on site
10 minutes
Nothing if the power cycle holds, which it usually does. A recurring fault traced to the control board is a part and a visit, at which point the age of the shower matters.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Mira fault codes
- EGet it checkedFlashing red and blue with Start/Stop off. The flow valve has failed, which is the component that lets water into the heater in the first place.Related: internal-components
- JGet it checkedStart/Stop lit, Status flashing red and white. Relay board failure — the board that actually switches the heating elements has failed.Related: internal-components
- HGet it checkedFlashing red and white with Start/Stop off. The cover PCB has failed — the board behind the front panel that reads the button and drives the lights.Related: internal-components
- GGet it checkedStart/Stop lit, Status flashing red and blue. The shower has decided the Start/Stop button is stuck in the pressed position.Related: internal-components
- AGet it checkedFlashing red on the Status light. Mira group three water-supply problems under this one code: no supply, low pressure, or a blockage somewhere in the outlet.Related: same brand
- DGet it checkedFlashing red and yellow. The outlet thermistor has seen a temperature above what Mira allow, and the shower has stopped rather than deliver it.Related: same brand
Own a Mira electric shower? Save it and its codes come first next time.
Related guides
Common questions about Mira I
How long should I leave the power off?
Fifteen seconds is a sensible minimum. A momentary flick at the cord often leaves the board powered through the interruption, which is why people report that the power cycle did not work when it was not really a power cycle.
It cleared and came back a week later. Is that normal?
Once is unremarkable. A pattern is not. Something is repeatedly putting the controller into that state, and it is worth investigating rather than resetting indefinitely.
Will a power cycle lose my settings?
No. Configuration on these units is held in non-volatile memory and in physical switch settings, so cycling the supply resets the running state rather than the setup.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.