Vaillant F.22 fault codewhat it means and how to fix it
Water pressure too low. Vaillant publish exact thresholds and two instructions: the indoor unit manual says inform your competent person; Vaillant UK’s fault page lets a competent owner top up to 1 to 1.5 bar.
Take care
What F.22 means
F.22 is the heat pump switching itself off because the heating water pressure has fallen too far, and the thresholds are published precisely. Below 0.7 bar you get a maintenance message, M32, which goes out on its own once pressure rises above 0.7 bar again. Below 0.5 bar for longer than one minute, the fault message F.22 and the current filling pressure appear alternately on the display, and that goes out when pressure rises back above 0.5 bar. Vaillant give 1 to 1.5 bar as the correct cold filling pressure, higher on a house of several storeys, and 0.7 bar as the minimum operating pressure.
What to do about it is where Vaillant’s own documents part company, and you should know all three. The operating instructions for the uniTOWER plus and the hydraulic station — the indoor units on aroTHERM plus and aroTHERM split systems — say that if the filling pressure falls below the minimum the heat pump is switched off automatically, and then: inform your competent person so that he can top up the heating water. The operating instructions for the earlier aroTHERM monobloc say the opposite in three words, "Top up with water", under checks carried out by the operator. And Vaillant UK’s owner-facing fault code page splits it by pressure: if the gauge shows less than 1 bar, this can be solved without an engineer if you are competent to do so, by locating the filling loop and slowly raising the pressure to between 1 and 1.5 bar, at your own risk; if it shows more than 1 bar and the fault is still there, it is a case for a Vaillant engineer, because the causes then are a faulty pressure sensor or its wiring, or the expansion vessel.
Two things are worth adding that Vaillant do not spell out on that page. Their own manuals strongly recommend antifreeze in parts of the installation at risk of frost, and some aroTHERM plus systems have a primary circuit filled with a propylene glycol mixture — topping those up with plain water dilutes the protection, which is a good reason to know what your system holds before you open a filling loop. And a heat pump circuit has a great deal more pipework than a boiler’s, so pressure that keeps needing attention means a leak to find rather than a level to correct. One last trap: the troubleshooting section of the same indoor unit manuals heads this fault F.723, "Building circuit: Pressure too low", while the display and the appendix call it F.22 and F.022. They are the same fault.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| A leak somewhere in the heating circuit | Vaillant’s appendix gives pressure loss in the building circuit due to leakages or air pockets as the first cause. A heat pump circuit has far more pipework than a boiler system, so there is more to leak from. | Common |
| Air vented out after recent work | The other half of Vaillant’s first cause. Any work on radiators or valves releases air that was taking up volume, and pressure drops as it goes. | Common |
| Pressure sensor or its wiring | Named in both the appendix and on Vaillant UK’s page: a defective building circuit pressure sensor, or loose, disconnected or faulty wiring to it. This is the version where the gauge reads fine and the fault is still on the screen. | Occasional |
| Expansion vessel losing its charge | On Vaillant UK’s cause list. Shows as pressure that swings widely between cold and hot rather than simply falling. An installer job. | Occasional |
| Pressure relief valve passing | Usually gives itself away as an occasional trickle from an outside discharge pipe. | Occasional |
What to try yourself
Read the pressure. On the indoor unit it is under Menu, Live Monitor, Water pressure; some systems also have a gauge. Below 0.5 bar is what produces this fault; below 0.7 bar produces the M32 maintenance message instead; 1 to 1.5 bar cold is where Vaillant want it.
Look for the leak. Check around radiator valves, under the indoor unit, and at any visible pipework — a small weep that dries between visits leaves a stain or a bloom of limescale.
Check whether an outside discharge pipe has been dripping. That points at the pressure relief valve rather than a leak in the house.
Decide whether to top up yourself. Vaillant UK’s page says you may, if you are competent, by locating the filling loop and slowly raising the pressure to between 1 and 1.5 bar. The indoor unit manual says to inform your competent person instead. If you know where the filling loop is, know the system is plain water, and this is the first time, the top-up is the same job as on a boiler. If any of those is not true, ring your installer.
Vaillant recommend antifreeze in parts of a system at risk of frost, and some aroTHERM plus installations have a glycol-filled primary circuit. Adding plain water to those dilutes the protection. If you do not know what your system was filled with, that is the reason to make the call rather than open the valve.If the pressure is above 1 bar and F.22 is still showing, do not keep adding water. Vaillant UK make that a Vaillant engineer case — the pressure sensor, its wiring or the expansion vessel — and topping up further only overpressurises a system that is not actually low.
Tell whoever attends how often it has happened. Pressure that needs topping up more than about once a year means a leak to find rather than a level to correct, and Vaillant’s own instruction is to identify and eliminate the reason for the loss.
Get an F-Gas certified heat pump engineer to look at your Vaillant F.22
We do not pass enquiries to a repair firm, so there is no form here. When you book an F-Gas certified heat pump engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.
What it costs to fix
Typical repair cost
£0–£450
Time on site
15 minutes
Nothing if you top it up yourself. An installer visit to repressurise and check is typically £90 to £150. Finding and fixing a leak, or replacing an expansion vessel or pressure sensor, runs from £150 to £450 depending on where it is.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Expansion vessel (8 litre, sealed system)
EV-8L£35–£85Plumbing merchant
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Vaillant fault codes
- F.532Get it checkedBuilding circuit flow rate too low, on the earlier aroTHERM monobloc. Vaillant list pressure, blockages, a dirty filter, balancing and air as causes, and send this one to your installer first rather than to Vaillant.Related: water flow
- F.788Get it checkedThe building circuit pump has detected a fault of its own and locked itself off. Vaillant’s first remedy is a thirty-second power-off, and the causes include dry running and a blocked filter.Related: water flow
- F.820Get it checkedConnection fault on the building circuit pump: the pump is not reporting any signal back to the heat pump. Vaillant’s remedy is the cable first and the pump second.Related: water flow
- Vapour from the outdoor unitUsually simple to fixA cloud rising off the outdoor unit is the defrost cycle. Vaillant’s own wording is that you do not have to do anything.Related: same brand
- Running all the timeUsually simple to fixA heat pump is meant to run long and low. The alarm signal is not the running time, it is the bill — and turning the thermostat up will not warm the house faster.Related: same brand
- F.511Get it checkedThe sensoCOMFORT controller has lost contact with the heat pump control module. Vaillant give two causes, a defective cable or a plug connection, and the house may stay warm while it shows.Related: same brand
Own a Vaillant heat pump? Save it and its codes come first next time.
Related guides
Common questions about Vaillant F.22
Can I top it up myself or not?
Vaillant say both, in different documents. The uniTOWER plus and hydraulic station operating instructions tell you to inform your competent person so that he can top up the heating water; the earlier aroTHERM monobloc’s operating instructions say "top up with water"; and Vaillant UK’s fault code page says an owner who is competent may use the filling loop to bring it to 1 to 1.5 bar, at their own risk, with a homeowner technical support line if you need help. The sensible reading is that a one-off top-up on a plain-water system is yours if you want it, and anything involving glycol, repeat losses or a pressure that is already above 1 bar is the installer’s.
What is the difference between M32 and F.22?
They are two thresholds on the same measurement. M32 is a maintenance message below 0.7 bar and the unit keeps running. F.22 is a fault below 0.5 bar held for more than a minute, and the heat pump switches off. Both go out on their own if pressure comes back up above their threshold — or, for F.22, once the blocking time has elapsed.
My manual says F.723. Is that the same thing?
Yes. The troubleshooting section of the uniTOWER plus and hydraulic station operating instructions heads the low pressure fault F.723, "Building circuit: Pressure too low", while the display shows F.22 and the appendix table lists it as F.022. The wording under all three is the same fault and the same thresholds.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
- Manufacturer support portal
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.