Vaillant Vapour from the outdoor unitwhat to check
A cloud rising off the outdoor unit is the defrost cycle. Vaillant’s own wording is that you do not have to do anything.
Before you start
What this means
This is the single most reported heat pump non-fault, and Vaillant answer it in one sentence: if you observe a cloud of vapour on the product, you do not have to do anything, and the effect may arise during the thawing process. It looks like smoke, it appears suddenly, and it usually happens on the coldest morning of the year, which is why people photograph it and ring somebody.
What is actually going on is worth understanding, because it also explains two other things owners notice. Below about five degrees outside, frost forms on the fins of the outdoor unit as it pulls heat out of damp air. Vaillant detect that automatically and thaw it at intervals by reversing the refrigeration circuit while the heat pump is running — which means, for a few minutes, the outdoor unit is being heated and the heat for doing it is taken from your heating system.
So the cloud of vapour is melted frost evaporating off a coil that has briefly become warm. And the two side effects are entirely normal: your radiators may go cool for a few minutes during a defrost, and you may hear the unit change note as it switches over. None of it is a fault. Persistent ice that never clears, or ice building up in the base tray beneath the unit, is a different matter and is worth a call.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Automatic defrost cycle running | Vaillant’s stated cause. Frost forms below about five degrees and the unit thaws it at intervals by reversing the circuit. | Common |
| Cold, damp weather | More moisture in the air means more frost and more frequent defrosts, so more visible vapour. | Common |
What to try yourself
Nothing. Vaillant’s own instruction is that you do not have to do anything.
If your radiators went cool at the same time, that is the same event — the defrost takes its heat from the heating circuit. It comes back within a few minutes.
Do not try to help it along. Never pour water on the unit or pick ice off the fins.
Daikin publish the general rule for all of these appliances: do not use any means to accelerate defrosting other than those the manufacturer recommends. On an R32 or R290 unit you are working next to a flammable refrigerant circuit with thin aluminium fins in front of it.Do check that leaves, snow and garden debris are clear of the air path, and that nothing has been stacked against the unit. That is a genuine owner job.
Call your installer only if ice never clears, or if it is building up in the tray under the unit rather than on the fins. That usually means a blocked condensate drain or a failed defrost. Vaillant UK’s one published exception to leaving ice alone is for the low pressure faults F.539 and F.554, where they allow an external heat source to be applied to the rear of the heat pump or to the condensate pipe — that is for a unit that has already locked out with a code, not for a routine defrost.
Get an F-Gas certified heat pump engineer to look at your Vaillant heat pump
We do not pass enquiries to a repair firm, so there is no form here. When you book an F-Gas certified heat pump engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.
What it costs to fix
Typical repair cost
£0
Time on site
5 minutes
Nothing. This is the system working as designed.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Vaillant fault codes
- F.22Get it checkedWater pressure too low. Vaillant publish exact thresholds and two instructions: the indoor unit manual says inform your competent person; Vaillant UK’s fault page lets a competent owner top up to 1 to 1.5 bar.Related: same brand
- Running all the timeUsually simple to fixA heat pump is meant to run long and low. The alarm signal is not the running time, it is the bill — and turning the thermostat up will not warm the house faster.Related: same brand
- F.511Get it checkedThe sensoCOMFORT controller has lost contact with the heat pump control module. Vaillant give two causes, a defective cable or a plug connection, and the house may stay warm while it shows.Related: same brand
- Sterilisation cycleUsually simple to fixVaillant call it the anti-legionella function: the cylinder is driven above 60 °C on set days, usually at 4 a.m., by the electric back-up heater. It looks like a fault and is not one.Related: same brand
- F.532Get it checkedBuilding circuit flow rate too low, on the earlier aroTHERM monobloc. Vaillant list pressure, blockages, a dirty filter, balancing and air as causes, and send this one to your installer first rather than to Vaillant.Related: same brand
- Radio communication interruptedGet it checkedA message from the wireless sensoCOMFORT VRC 720f, not from the heat pump. Vaillant’s first instruction is to make sure the power supply is on; the second concerns reception strength.Related: same brand
Own a Vaillant heat pump? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.