Solar or battery system Generating less than expectedwhat to check
The rated figure is a laboratory number a British afternoon rarely supplies. Two published non-faults explain most of the rest: darkness and export limits.
Before you start
What this means
A system generating well below its rated output is usually reporting the weather and the laws of physics rather than a fault, and the reason people are surprised is that the headline number is measured under conditions this country does not often provide. A panel’s rated output is established at a standard test condition — a specific irradiance and a specific cell temperature — and a real roof in Britain rarely meets both at once. Bright and cold beats bright and hot, because panel output falls as cells heat up, which is why a clear March day can outperform a hazy July one.
Two published non-faults account for a large share of the remaining confusion, and both are about darkness. SolarEdge publish a Night Mode status that appears when the input voltage is below six volts direct current, which is simply the inverter recognising that there is nothing to convert and standing down; their own troubleshooting note is to test the DC side only if the status persists in daylight. An inverter that goes dark in the evening and stays dark until morning has not failed to restart. Enphase publish the related point for their microinverter systems: if there is insufficient sunlight to power up the microinverters, they cannot communicate with the IQ Gateway, so the gateway’s communications light can sit solid red at dusk and dawn and the app can look as though it has lost half its panels while the system is entirely healthy.
Beyond that, the practical causes are the mundane ones and they are worth checking in order of how much they cost to fix. Shading is the big one and it changes through the year, so a system commissioned in June can be shaded by a neighbour’s tree in October when the sun is lower. Soiling matters more than people expect on shallow-pitched roofs, where rain does not run off effectively. Export limiting caps what the system is allowed to push out, which is a setting rather than a fault: Solis show it as the status LimByEPM, inverter under external control, and Fox ESS describe a soft limit that holds export below the set value within fifteen seconds. And a single underperforming string or microinverter will reduce the total without stopping it, which is the case worth chasing because it does indicate something real; Enphase’s own production-fault logic is that none producing points to the grid or the wiring, all on one branch points to that branch, and one or a scattered few point to the individual connections. The way to tell a fault from the weather is to compare like with like. One clear day this year against one clear day last year, at the same time of year, is far more informative than any absolute figure.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Weather and season | The rated figure comes from a standard test condition rather than a British afternoon. Cloud, haze and low sun angles all reduce output without anything being wrong. | Common |
| Heat reducing panel output | Panels produce less as they get hotter, which is why a cold bright day can beat a hot one. It surprises people who expect summer to be uniformly better. | Common |
| Shading that has changed with the season | A system commissioned in summer can be shaded by the same tree or building in autumn, because the sun is lower. Growth over a few years does the same thing. | Common |
| Export limiting configured on the system | A cap on how much can be pushed to the grid. Solis show it as the status LimByEPM, "inverter is under external control", and Fox ESS publish soft and hard export limits in their user manual. It is a setting made at installation rather than a failure. | Occasional |
| One string or microinverter underperforming | The case worth chasing. It reduces the total without stopping generation, so it hides in the overall figure unless you look at the per-string or per-panel data. | Occasional |
What to try yourself
Compare against the same period last year rather than against the rated figure. A clear day this March against a clear day last March tells you far more than any absolute number.
Look at per-string or per-panel data if your monitoring provides it. A single underperforming section is the finding that actually indicates a fault.
Go outside around midday and look for shade on the array. Shading changes with the season and with anything that has grown or been built since the system went in.
Check whether export limiting is set. It caps what the system is allowed to send out and is a configuration rather than a fault; on a Solis inverter it shows as LimByEPM.
Ignore an inverter that goes dark overnight. SolarEdge publish a Night Mode status for input voltage below six volts, and Enphase publish that their microinverters cannot communicate with the gateway without sufficient sunlight — both are normal.
If one section is genuinely down, or output has stepped rather than drifted, contact your installer with the monitoring data. A step change is much easier to diagnose than a gradual one.
Get a registered electrician to look at your solar or battery system
We do not pass enquiries to a repair firm, so there is no form here. When you book a registered electrician, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.
What it costs to fix
Typical repair cost
£0–£200
Time on site
45 minutes
Nothing for weather, season or settings, which is most of it. An installer visit if the monitoring shows a genuine step change or one section down against the others.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Own this appliance and had this code? . Nothing is published until a person has read it.
Related solar or battery system fault codes
- Inverter shutting down in the middle of the dayUsually simple to fixUsually the grid rather than your system. Inverters must disconnect when mains voltage goes outside the G98 protection settings, and exporting solar is what pushes it there.Related: same brand
- Battery not dischargingGet it checkedBefore treating it as a fault, check what your tariff is asking. A battery holding charge in the evening is very often following a schedule correctly.Related: same brand
- Panels are still liveStop — call an engineerThere is no switch that stops a panel generating. Turning the inverter off makes it safe to stand next to and leaves the roof wiring live at hundreds of volts.Related: same brand
Related guides
Common questions
Why do I never see the rated output?
Because that figure is measured under a standard test condition rather than in a British garden. It assumes a level of irradiance and a cell temperature that rarely occur together here, and panels lose output as they warm up, so peak conditions on paper and peak conditions on your roof are different things.
Half my panels vanished from the app in the evening.
On an Enphase microinverter system that is expected. Enphase publish that if there is insufficient sunlight to power up the microinverters, they cannot communicate with the IQ Gateway, so panels drop off the display as the light fades and reappear in the morning. Nothing has failed and there is nothing to restart. If the communications light stays red in full daylight, that is a different matter and worth a call.
Should the inverter come back on by itself in the morning?
Yes, and it will. SolarEdge publish a Night Mode status for input voltage below six volts DC, which is simply the inverter standing down because there is nothing to convert. It wakes when there is enough light, without intervention.
How do I know if it is worth calling somebody?
Look for a step rather than a drift. Output that dropped noticeably on a particular date, or one string producing far less than its siblings, is worth investigating. Output that is simply lower than you hoped, across the whole array, in winter, usually is not.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer support portal
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.