SMA Inverter not connecting to the gridwhat to check
SMA disable the grid connection deliberately when a pre-start check fails. The event number in the Results menu is what tells you which check.
Take care
What this means
An SMA inverter that will not connect and start generating is often not broken but blocked, and the distinction matters because it changes what you do next. SMA run checks before connecting to the grid and disable the connection if one fails — their wording for the insulation case is that if the values are below the specified threshold, the grid connection is disabled to prevent ground faults. The system sits there, apparently dead, having made a decision. The problem for an owner is that modern SMA inverters have no display, so all you get is a light. SMA connect the two for the most serious family: if the red LED is glowing and event 3501, 3601 or 3701 shows in the Results menu, there may be a ground fault present. But a light on its own cannot tell you which of several conditions applies, and the answer is in the event number rather than the colour. There are two places to find it and both are worth knowing. The inverter has its own web user interface with a Results menu, reached over the local network. And if the system is registered, Sunny Portal carries the event messages in the system logbook or event monitor.
SMA describe both as valid routes. Getting the number changes the conversation entirely, because it separates a grid condition from a DC-side fault from a communication problem, and those go to three different people. The Sunny Boy 3.0 to 6.0 operating manual names the ones that produce exactly this symptom. Event 1302 is waiting for grid voltage, check grid and fuses — SMA's explanation is L or N not connected, and their first corrective measures are to ensure the line conductors are connected and the miniature circuit breaker is switched on. Event 1501 is a reconnection fault, where the country data set or a parameter does not match local requirements and the inverter cannot connect. Events 3302 and 3303 are unstable operation: not enough power at the DC input for stable operation, so it cannot connect. And events 3901 and 3902 are waiting for DC start conditions, which SMA's own article describes as typically appearing at dawn and dusk, when the inverter's electronics are awake but the array is not yet delivering enough voltage, with the corrective measure that it is generally sufficient to wait for more light, or to check for snow in winter.
The green LED flashing two seconds on and two off is SMA's waiting-for-feed-in-conditions signal for the same state, and green and red flashing together means no country data set is configured. A structural observation that helps when you are reading a list: SMA's event numbers run in bands. The 35xx range covers insulation, 36xx leakage current, 37xx residual current, and the 6001 to 6499 and 77xx ranges are self-diagnosis events whose cause, in SMA's words, must be determined by the Service. That banding is an inference from the article set and the manual rather than a legend SMA publish, but it is a reliable orientation. Two honest limits. SMA's articles are model-specific, so the same event number has separate articles for different inverter families and the family matters. And part of their event documentation sits behind an installer login, which means some detail is genuinely not public.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| A pre-connection check has failed | SMA disable the grid connection when the insulation measurement falls below threshold, which leaves the system looking dead rather than reporting an obvious failure. | Common |
| A grid condition or a tripped breaker on the AC side | SMA’s event 1302, waiting for grid voltage, is explained as L or N not connected, and their corrective measures start with making sure the miniature circuit breaker is switched on. A network outside its limits produces the same silence, usually intermittently and by time of day. | Common |
| Not enough light to start | Worth ruling out before anything else. SMA’s events 3901 and 3902, waiting for DC start conditions, typically appear at dawn and dusk when the array voltage is not yet enough to feed in, and their corrective measure is to wait for more light or check for snow. The green LED flashing slowly is the same message. | Common |
| A DC-side fault in the insulation or residual current family | The serious case, and the one SMA tie to the red LED together with an event number in the Results menu. | Occasional |
| A communication fault rather than a generation fault | A system generating happily but not reporting looks identical from inside the house. The Sunny Boy 3.0 to 6.0 manual lists communication timeouts at 8708 to 8710, and the green LED glowing or pulsing tells you the inverter is feeding in whatever the portal says. | Occasional |
| No country data set, or a changed parameter | SMA’s event 1501 is a reconnection fault: the country standard or a parameter does not match local requirements and the inverter cannot connect. Green and red flashing together is their signal that no country data set is configured at all. Both are installer settings. | Occasional |
What to try yourself
Check the light on the inverter and note the colour. It will not tell you which fault you have, but a glowing red is what SMA tie to the ground fault family.
Find the event number. It is in the Results menu of the inverter’s own web interface, or in the system logbook or event monitor in Sunny Portal if the system is registered.
Note whether the system generated at all today and whether it stopped or never started. A failure to connect and a mid-day dropout point at different event families.
Rule out the obvious — heavily overcast conditions, early morning, or a tripped breaker on the AC side of the inverter. A green LED flashing two seconds on and two off is SMA’s waiting-for-feed-in-conditions signal, and their advice for the dawn-and-dusk events 3901 and 3902 is simply to wait for more light.
If a restart is worth trying, do it the way SMA publish it for owners: switch off the inverter’s circuit breaker in the consumer unit or sub-distribution board overnight and switch it back on the next morning. SMA’s reason for the overnight wait is that the inverter is then disconnected on the DC side as well, because nothing is generated at night, and the capacitor discharge time has been observed. Their other route, disconnecting the inverter from its voltage sources in daylight, is one they say to ask your installer for.
Switching the breaker off makes the inverter safe to stand next to. It does not make the array safe — the DC side stays live in daylight, and SMA warn against touching the cables, the substructure, the frame or the modules where a ground fault may be present. Do not operate the DC switch on the inverter as part of this.Give the event number to your installer rather than describing the light. It is the single piece of information that tells them what to bring.
Get a registered electrician to look at your SMA solar or battery system
We do not pass enquiries to a repair firm, so there is no form here. When you book a registered electrician, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.
What it costs to fix
Typical repair cost
£0–£300
Time on site
45 minutes
Nothing if it is light, weather or a tripped breaker. An installer visit once there is a DC-side event number, and considerably more if a fault has to be traced across the array.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Own this appliance and had this code? . Nothing is published until a person has read it.
Related SMA fault codes
- 3501Stop — call an engineerInsulation resistance too low. SMA are unusually direct: the error is not caused by the inverter, it is in the DC installation — and it can come and go with the weather.Related: same brand
- 3701Stop — call an engineerResidual current. Unlike the insulation event this one trips a running system, and SMA publish the threshold: a sudden jump of 30 milliamps or more.Related: same brand
Own a SMA solar or battery system? Save it and its codes come first next time.
Related guides
Common questions
Where exactly do I find the event number?
Two places, both published by SMA. The inverter has its own user interface reached over your local network, and the number appears in the Results menu. Alternatively, if the system is registered, the event messages appear in the system logbook or event monitor in Sunny Portal.
Why does my inverter not have a screen?
SMA moved away from displays on modern units, which is why the diagnostic route is the web interface and the portal rather than a panel on the box. The LED remains as an at-a-glance indication and SMA do link it to the ground fault events, but it cannot distinguish between the conditions on its own.
Do the numbers mean the same thing on every SMA inverter?
For the ground fault family, yes, as far as SMA’s published manuals go: 3501, 3601 and 3701 carry the same meanings in the Sunny Boy 3000TL-21, Sunny Boy 1.5 to 2.5, Sunny Boy 3.0 to 6.0, Sunny Tripower 3.0 to 6.0 and Sunny Tripower X manuals. But SMA still publish model-specific articles for the same number — their 3701 article for one Sunny Tripower US range adds a parameter cause the general article does not have — so knowing whether you have a Sunny Boy or a Sunny Tripower, and which generation, still matters when you look one up.
Can I see everything SMA publish about my event?
Not always. Some of SMA’s event articles state on their face that additional information is available to installers who log in, so part of the documentation is genuinely behind a login. What is public covers the insulation and residual current family well; other bands are thinner.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer support portal
- Manufacturer technical and service documentation
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.