Electric shower not working

An electric shower fails in five distinguishable ways, and two questions — is the neon lit, is water flowing — tell you which one you have before anyone opens anything.

What it usually means

An electric shower is a simple machine doing a hard job. Cold mains water enters, passes over one or more heating elements, and leaves hot, all in the length of the unit and in real time. There is no tank and no stored hot water, which is why it works during a boiler breakdown and why it needs an enormous electrical supply: a 9.5 kW unit draws around 40 amps continuously, making it the biggest single load in most houses. It has no plug. Its supply comes on its own heavy circuit through a ceiling pull cord or a wall switch, and that is the only isolation you have.

Because the water side and the electrical side are independent, the useful diagnosis is to work out which one has stopped. Pull the cord and press start. If the indicator neon lights, the supply is arriving and the unit is alive, and the fault is downstream. If nothing lights at all, the fault is upstream of the shower: the pull cord itself, which switches 40 amps in a damp ceiling and is a genuine wearing part, the 40 or 45 amp breaker in the consumer unit, or a residual current device that has tripped.

Water not flowing with the neon lit points at the plumbing side, and there is one design detail behind most of these. A shower will not energise its elements until it can prove water is moving through them, using a pressure or flow switch, because heating a dry element destroys it in seconds. So a shower short of flow does not run cool — it does nothing at all, which reads exactly like an electrical failure. Behind the unit or above it there is usually an isolating valve, often with a screwdriver slot, and inside the inlet there is a filter that collects grit and scale. Both are common, and both are ahead of any electrical component in the queue.

Water flowing but never warming is the third pattern, and it means the elements are not being energised or have failed. In hard water areas that is the ordinary end of a shower's life: scale builds on the element until it overheats locally and either the element fails or a thermal cut-out takes it out of circuit permanently. Which brings up the honest economics. Electric showers are consumable appliances, and once the element or the control has gone on a unit that is eight or ten years old, replacement is usually the better spend. One caution if you replace it: a higher kW model is not a like-for-like swap, because the existing cable and breaker were sized for the old one.

The remaining two patterns are the ones to stop for rather than diagnose. A shower that trips the breaker or residual current device is reporting current leaking to earth, and the usual path is through the water inside a failing element. A shower leaking from the casing rather than from a hose or the head has mains water loose inside an enclosure that contains the terminal block. Neither is a "keep using it for now" situation.

How to narrow it down

Work through these in order.

Does the indicator light come on when you pull the cord and press start?

This is the single most useful test on the appliance, because the neon is fed from the same supply as the elements. Lit means power is arriving and the fault is inside the shower or on the water side. Nothing at all means you are looking at the pull cord, the breaker or the wiring, and that is an electrician rather than a plumber.

Does water come out at all?

If it does not, check the shower is not simply isolated. There is normally a valve on the inlet pipe behind or just above the unit, sometimes hidden by the cover plate, and it gets turned off for other work and forgotten. Then check the filter in the inlet and the head and hose for scale, because a shower that cannot prove flow will not fire.

Do the cold taps elsewhere in the house run strongly?

Run the kitchen cold tap and see. Showers have a minimum working pressure and flow, and below it they refuse to operate rather than running cool. Weak flow everywhere points at a stopcock not fully open, work on the street main, or a whole-house filter — none of which is a shower fault.

Does it flow but stay cold?

That is a different fault from a dead shower and a much shorter list: an element that has failed, a thermal cut-out that has operated, or a control that is not switching the elements on. Note whether it is stone cold or merely lukewarm, because lukewarm on a two-element shower often means one element has gone rather than both.

Has it tripped a breaker or an RCD?

If it has, do not keep resetting it. That device has detected current going somewhere it should not, and on a shower the usual route is through the water in a failing element. Leave the circuit off and have it looked at — this is the branch of this fault that is genuinely dangerous rather than merely inconvenient.

Is there any smell of hot plastic, or discolouration at the pull cord or the shower?

Look at the cord switch on the ceiling and the cable entry on the unit. Browning, a switch that feels warm, or a smell of hot plastic on a 40 amp circuit is a connection heating up, and it wants isolating now rather than at the weekend. It is also a specific thing to tell whoever you call.

Is water escaping from the casing rather than from the hose or head?

Stop using it and isolate it. The manufacturers say the same thing, and the reason is that the terminal block and the element connections are inside that enclosure. A drip from the small pipe underneath is different again: that is the pressure relief device having done its job, and it needs a look rather than an emergency.

How old is it, and is your water hard?

Both answers change what is worth doing. Scale is what kills electric showers, and a unit approaching ten years old in a hard-water area with a failed element is usually a replacement rather than a repair. If you do replace it, keep the same kW rating unless an electrician has confirmed the cable and breaker will take more.

Codes commonly shown with this

When it is urgent

Take care

No shower is inconvenient rather than dangerous, and most of this can be worked through calmly. Three findings change that. A shower that trips its breaker or residual current device is reporting current leaking to earth, and repeatedly resetting it removes the only protection standing between that fault and the person in the shower — leave the circuit off. A smell of hot plastic, or a discoloured or scorched pull cord, is a connection overheating on a 40 amp circuit and wants isolating immediately. And water escaping from the casing rather than the hose puts mains water inside the enclosure that holds the terminal block, which the manufacturers say is a stop-using-it fault. There is no plug to pull: isolate at the pull cord or wall switch, and if you cannot find one, at the largest breaker in the consumer unit. Replacing a shower on its existing circuit is a repair and not notifiable, but a bathroom is a special location under Approved Document P, so altering the circuit is notifiable work normally done by a scheme-registered electrician.

What it costs

Typical repair cost

£90–£350

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Get an engineer to look at this