Worcester boiler with no hot water

On a Greenstar there are two settings and one dial that produce this complaint without anything being broken, and they are worth checking before the diverter valve gets blamed.

What it usually means

Worcester Greenstar boilers have a handful of features of their own that produce exactly this symptom, so it is worth going through those before reaching for the usual explanations. The most useful thing to establish first is whether the heating still works. Heating fine and no hot water puts the fault on the hot water side specifically, and on a combi that is a short and well-known list. Neither working is a different question about the appliance as a whole.

Start with the preheat setting, because it is Worcester's own and it changes the experience without changing anything mechanical. A Greenstar can be run in a comfort mode, where the boiler keeps its exchanger warm so hot water arrives quickly, or in an economy mode, where it waits until you actually draw water before firing. In economy the water genuinely takes noticeably longer to come through, and a household used to the other setting reads that delay as a failure. Switching between the two is a control setting rather than a repair.

Then look at the hot water temperature control itself. On several Greenstar models this is not marked in degrees but as a numbered scale, and it is entirely possible for it to have been knocked down to its lowest position — by cleaning, by a child, or by somebody adjusting the wrong dial. It produces water that is present and warm rather than absent, which is the version of this complaint most often misattributed to a failed part.

Next, the flow rate needed to make it fire at all. A combi only heats water when it detects water moving, and there is a minimum below which nothing happens. If a tap has scaled up, or a spray head or an aerator is partly blocked, the flow can fall under that threshold and the boiler will never light for hot water — the giveaway is that a full-bore bath tap works and a restricted basin tap does not. That is a two-minute check with a bucket and it eliminates the most expensive theories.

Only then the parts. Worcester publish a code specifically for a failed hot water temperature sensor, which produces the classic pattern of heating carrying on normally while hot water stops, and it is worth looking up because it names the fault outright. The other common mechanical cause on a combi is the valve that decides where the heat goes: stuck towards the heating circuit, you get hot water only while the heating is running, and stuck the other way you get radiators that stay cool. And in hard water areas the plate that transfers heat into your tap water scales up gradually, producing a decline over months rather than a failure on a particular day.

Two Greenstar specifics are worth knowing before you call. Models without a display use a blue light, and the way it flashes is the fault code — that pattern is worth writing down, because it is information nobody thinks to record. And if you have a Greenstar system boiler with a separate cylinder rather than a combi, most of the above does not apply: your hot water is made by a cylinder, a cylinder thermostat and a motorised valve, and those are the first three things to look at.

How to narrow it down

Work through these in order.

Does the heating still work?

Establish this before anything else, ideally by running the heating for ten minutes even in summer. Heating working with no hot water points at the hot water side alone — the sensor, the diverter valve, the plate heat exchanger or a flow problem. Neither working points at the appliance as a whole, and pressure is then the first thing to read.

Is the boiler set to its economy or its comfort preheat mode?

Worcester give you both. In comfort mode the boiler keeps itself warm so water arrives quickly; in economy it waits for you to open a tap before firing, which makes the water take appreciably longer. If somebody changed it to save money, the delay is the setting working rather than the boiler failing.

Where is the hot water temperature control set?

On several Greenstar models this is a numbered dial rather than one marked in degrees, which makes it easy to knock down without noticing. Turn it up, run a tap for a couple of minutes and see. Water that is warm but not hot is much more often this than any component, and it costs nothing to rule out.

Does a bath tap work when a basin tap does not?

Test both. A combi needs a minimum flow through it before it will fire for hot water, so a scaled spray head, a blocked aerator or a partly closed isolating valve can leave the boiler apparently dead on hot water at one tap and perfectly normal at another. It is the cheapest finding on this page.

Do you get hot water only while the heating is on?

That specific pattern points at the valve that directs heat between the two circuits being stuck towards heating. It is a recognised failure on combis, the part is not enormous, and describing the symptom in exactly those words on the phone will get you an engineer who arrives with the right thing in the van.

Is there a code on the display, or a blue light flashing?

Write down exactly what you see. Worcester publish a code specifically for a failed hot water sensor, which explains heating working while hot water does not. On Greenstar models with no display the blue light is the fault code and the flashing pattern is the message, so note the rhythm before switching anything off.

Has the hot water been getting gradually worse for months?

A slow decline, rather than a stop, is the signature of scale on the plate that transfers heat into your tap water. It shows up first as water that is hot enough in summer and disappointing in winter, when the incoming mains is colder. Hard water areas see this on a five to ten year cycle.

Do you have a combi or a boiler with a hot water cylinder?

If there is a cylinder in a cupboard, your hot water is made there and not inside the boiler, so the diverter valve and the plate heat exchanger are irrelevant. Look instead at the cylinder thermostat, the motorised valve on the pipework near it, and whether the programmer is actually calling for hot water.

Codes commonly shown with this

When it is urgent

Take care

Not an emergency on its own — no hot water with working heating is inconvenient rather than dangerous, and the settings checks above are all safe and free. Three things change that. If the boiler has locked out on a code, note it and do not reset it more than twice: repeated resets on an ignition fault release gas into the appliance each time, and repeated resets on an overheat fault damage the most expensive component in it. If water is coming out of the boiler itself rather than from pipework beneath it, switch it off and get it looked at. And if you can smell gas, do not touch any switch — leave the property and ring the emergency line from outside. Everything behind the casing is gas appliance work and is legally restricted in Great Britain to Gas Safe registered engineers, which covers the diverter valve, the sensor and the plate heat exchanger alike. Doing it yourself is an offence rather than merely unwise, so the useful contribution is the diagnosis: which taps, which mode, what the display or the blue light showed, and whether the heating still works.

What it costs

Typical repair cost

£120–£450

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Get an engineer to look at this

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead