Samsung tC5 fault codewhat it means and how to fix it

Get it checkedTumble dryerHeat pump machines. A compressor temperature sensor exists only where there is a compressor, so vented and condenser dryers do not carry this codeLast updated

The sensor watching the compressor temperature is not reporting properly. Samsung ask for a longer pause than usual before you try again.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a qualified appliance engineer to look at the Samsung properly.

What tC5 means

Samsung give this as "Compressor temperature sensor problem" and their instruction is slightly different from the rest of their range: wait two to three minutes, turn the power back on and start again, then check for a clogged lint screen and a restricted vent system.

The wait is the interesting part. Everywhere else Samsung ask for thirty seconds, and the reason for asking longer here is that the sensor is measuring something that takes time to settle — a compressor that has been running is genuinely hot, and a reading that looks impossible while it is hot may be perfectly sensible once it has cooled. So a proportion of these clear themselves given a few minutes, which is worth knowing before you conclude the machine is broken.

The rest divide into two. Either the sensor really has failed, in which case the machine has lost sight of a component it needs to protect, or the compressor genuinely is running too hot and the sensor is the messenger — which brings you back to airflow, filters and the heat exchanger, exactly as Samsung’s own checks suggest. That is why their instruction mentions the lint screen on what is nominally a sensor fault.

What causes it

Causes of the Samsung tC5 fault code, most common first
CauseWhat is actually happeningHow likely
The compressor was hot and the reading had not settledSamsung’s two to three minute wait exists for this. A sensor reading taken while the compressor is at working temperature can fall outside the range the board expects without anything being wrong.Common
Restricted airflow is genuinely overheating the compressorSamsung include a lint screen check on this code, which tells you they see it. The sensor is reporting accurately and the fault is upstream, in the filter or the heat exchanger.Common
The sensor or its wiring has failedA thermistor that has gone open or short circuit produces a value the board rejects outright. This is the version that returns immediately after every reset rather than clearing on its own.Occasional
A control board input faultLess common, and indistinguishable from a failed sensor without test equipment. It matters only because it changes the price of the repair rather than the diagnosis.Rare

What to try yourself

  1. Take the washing out and spread it, then leave the machine switched off for two to three minutes rather than the thirty seconds Samsung ask for on other codes.

  2. While you wait, clean the lint filter. Samsung include this on a sensor code for a reason: a hot compressor is usually a starved compressor.

  3. Open the lower front flap and check the heat exchanger for lint, cleaning it if the fins are furred.

    Gloves on, and no hard vacuum attachments against the fins.
  4. Check nothing is blocking airflow around the machine, and that it is not shut in a cupboard with no ventilation.

  5. Turn it back on and run a short programme. A code that clears and does not return was a settling problem rather than a fault.

  6. If tC5 returns immediately every time, stop resetting and book someone. A sensor that has genuinely failed will not recover, and the machine is running without a temperature reference in the meantime.

Get a qualified appliance engineer to look at your Samsung tC5

We do not pass enquiries to a repair firm, so there is no form here. When you book a qualified appliance engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What it costs to fix

Typical repair cost

£0–£240

Time on site

20 minutes

Free if it settles or if it was airflow. A temperature sensor is an inexpensive part with most of the bill being the visit, and a board fault is the expensive outcome.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Samsung tC5

Why does Samsung want three minutes rather than thirty seconds?

They do not explain it, but the sensible reading is that the compressor needs time to cool before the reading means anything. Everywhere else in their range thirty seconds is the standard, and the exception here lines up with a fault about temperature.

It shows TC5 in capitals.

Same code. Samsung’s DV90F24 manual writes it as TC5, TC7 and TCA in capitals and their support page and other manuals write tC5 with a small t. Their documents are simply inconsistent about case, and the letters are what matter.

Is there a similar code for a different sensor?

Several, and some are only in the manuals. tC is the air temperature sensor and is on Samsung’s website; tC7, which they gloss as the "Eva In" sensor at the evaporator inlet, appears in manuals but not on the site at all. If your code is tC7 and you found nothing on Samsung’s site, that is why.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer support portal
  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?