Daikin E6 fault codewhat it means and how to fix it

Get it checkedAir conditionerLast updated

The compressor failed to start. It sits in Daikin’s outdoor unit group alongside the overload and pressure codes, and all of them are certified work.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get an F-Gas certified heat pump engineer to look at the Daikin properly.

Get an F-Gas certified heat pump engineer to look at your Daikin E6

We do not pass enquiries to a repair firm, so there is no form here. When you book an F-Gas certified heat pump engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What E6 means

E6 is published by Daikin under the OUTDOOR UNIT heading as faulty compressor start-up. The compressor is the part that actually does the work in an air conditioner — everything else moves air or moves refrigerant around it — so a compressor that will not start means a system that will not cool, however healthy the rest of it looks. The indoor unit will usually carry on blowing, which is what makes this present as poor performance rather than a breakdown. A compressor can fail to start for reasons that range from cheap to terminal, and the distinction is not something you can make from the garden.

Daikin’s service manual calls this code Compressor Lock, detects it from the current waveform when the inverter applies a high-frequency voltage to the motor, and gives three supposed causes: a closed stop valve, a locked compressor, and a disconnected compressor harness. Only the middle one is the compressor itself. A stop valve left closed or partly closed after installation or service work will produce it on a perfectly good machine, and a harness or the board driving it is an electrical repair rather than a compressor. These are inverter compressors driven directly by the outdoor board, so there is no start capacitor to fail — the electrical end of the list is the harness and the board. It may be mechanical, where the compressor is seized or the motor windings have failed, which is the expensive end. Or it may be a protective refusal, where the system has detected conditions under which starting would cause damage and has declined. That last case is why the codes around it matter.

Daikin publish a cluster of related outdoor unit faults, and they belong to the same conversation: E5 for an overload having started, F3 for high discharge pipe temperature, F6 for high pressure control in cooling, L5 for output overcurrent, and L4 for high temperature at the inverter heatsink. Several of those point at conditions rather than components — a system that is overheating, over-pressured or drawing too much current is often reacting to something else, such as restricted airflow at the outdoor unit or a refrigerant problem. What you can usefully do before calling anybody is limited but not worthless. Confirm the outdoor unit has clear space around it and is not smothered by planting, fencing or debris, because a unit that cannot reject heat will trip protections repeatedly. And note whether the fault is intermittent or permanent, because that genuinely helps. Beyond that, this is inside a sealed refrigerant circuit and a mains electrical enclosure.

What causes it

Causes of the Daikin E6 fault code, most common first
CauseWhat is actually happeningHow likely
A closed stop valveFirst on Daikin’s list, and the cheap answer. The service valves on the outdoor unit are closed for installation and service work; one left shut, or not fully open, stops the compressor dead. Common on a system that has just been fitted or worked on.Common
A disconnected compressor harness or a failing outdoor boardDaikin’s third cause, and the electrical end of the list. The compressor itself is undamaged — it simply is not getting what it needs to start turning. Daikin’s flow disconnects the U, V and W harnesses and tests the inverter before condemning anything.Common
The system protecting itselfDaikin publish neighbouring codes for overload, high discharge temperature, high pressure and overcurrent. A refusal to start can be a reaction to conditions rather than a component failure.Occasional
Restricted airflow at the outdoor unitA unit that cannot reject heat runs hot and trips protections. Planting, fencing, covers and packed fins all do it, and this is the one cause you can see.Occasional
A refrigerant problemNot on the split service manual’s list for this code, but Daikin’s heat pump service documentation for the same E6 names refrigerant overcharge or shortage, a clogged circuit and non-condensables among its causes. It ties this code back to the refrigerant family, and it is certified work either way.Occasional
A seized compressor or failed windingsThe terminal case. On an older system this is usually the point at which replacing the unit is compared against repairing it.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£150–£1,200

Time on site

2h 30m

A stop valve opened or a harness reconnected is a call-out charge. A compressor replacement is at the top, and on an older split it frequently costs more than the system is worth.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Daikin E6

Does this mean I need a new compressor?

Not necessarily, and it is worth not assuming so. Two of Daikin’s three published causes for this code are not the compressor at all: a closed stop valve and a disconnected compressor harness. A stop valve is opened with a spanner, a harness is reconnected, and a system declining to start because it has detected a condition it does not like is a third possibility. Get it diagnosed before anyone quotes for the compressor.

The indoor unit still works. Is that a good sign?

It is normal rather than reassuring. On a Daikin split the indoor unit is fed from the outdoor unit, so a lit indoor unit tells you the outdoor unit has power, and its fan will blow air regardless of what the compressor is doing. What it cannot do is make that air cold, because all the cooling happens outside.

It starts sometimes and not others.

Intermittent is genuinely useful information, so tell whoever attends. A hard failure points at the compressor or its windings; an intermittent one points more often at a loose harness, a supply problem, or a protection tripping under particular conditions such as a hot afternoon. Daikin’s manual says the code clears itself after about eleven minutes of continuous running without another error, which is why an intermittent one can seem to come and go.

Should I keep trying it?

No. Repeatedly attempting to start a compressor that will not start puts heat and current through it and can turn a repairable fault into a replacement. Note the code, stop using the system, and get it looked at.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.