Daikin U0 fault codewhat it means and how to fix it
Refrigerant shortage. The circuit is sealed, so if it is short it has leaked — and this is certified work by law, not a top-up.
Take care
Get an F-Gas certified heat pump engineer to look at your Daikin U0
We do not pass enquiries to a repair firm, so there is no form here. When you book an F-Gas certified heat pump engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.
Which Daikin appliance is showing U0?
The right answer depends on what you can see. Pick the one that matches.
Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.
A wall-mounted air conditioner with a remote control
This page is yours. The circuit has leaked, and finding and repairing the leak is certified work.
Stop using the system and book an F-Gas certified engineer; ask for the leak to be found, not just a recharge.
An Altherma heat pump with radiators or a hot water cylinder
Same two characters and the same headline, refrigerant shortage, but the outdoor unit, the R32 charge and the water circuit around it are the Altherma’s.
Use the Daikin U0 page in the heat-pumps section of this site instead.
What U0 means
U0 is published by Daikin under the SYSTEM heading as refrigerant shortage, and the single most useful thing to understand about it is what it implies. A refrigerant circuit is sealed. The gas is not consumed, it does not wear out and it is not a consumable like oil in a car. If there is less of it than there should be, it has escaped, which means there is a leak somewhere in the pipework, the joints, the coils or the valves. That is why the honest answer to this code is never simply a top-up. Recharging a leaking system puts the gas back for a season and then loses it again, and it leaves the actual fault in place. It is also why this is not a job anybody can do. Handling fluorinated refrigerant requires certification in this country, and that covers exactly what this fault needs — leak detection, recovery, evacuation and recharge. It is a legal requirement rather than a manufacturer preference, and it exists because these gases have a significant environmental effect when released. An installer who offers to top your system up without finding the leak is offering something they should not.
What you will notice from the room is gradual rather than sudden. Cooling falls off over weeks, the system runs for longer to achieve less, ice may form on the pipework or the indoor coil, and the electricity cost rises because the compressor is working continuously. That gradual onset is characteristic and helps distinguish it from a component failure, which tends to be abrupt. One caution before anyone reaches for gas: the unit does not measure refrigerant directly.
Daikin’s service manual describes U0 being inferred three ways — from the input current against the compressor speed, from the discharge pipe temperature against the expansion valve opening, and from the difference between suction and discharge temperatures — and the troubleshooting flow accordingly starts with the thermistors, then a closed stop valve, then the flare joints and the pipework, before concluding that refrigerant is short. A faulty thermistor or a stop valve left partly closed after work will produce this code with a full charge. The current FTXM and RXM domestic ranges are charged with R32 — the operation manual opens with the statement that the appliance is filled with it — while Daikin’s service documentation also covers R410A and older R22 models; R32 and R410A are both fluorinated gases under the same certification rules, and R32 is additionally classed as mildly flammable. Daikin publish several related outdoor unit codes that also point into the refrigerant circuit and are worth recognising as the same family: E5 for an overload start, E6 for faulty compressor start-up, F3 for high discharge pipe temperature, F6 for high pressure control in cooling, and EA for a cooling-heating switching error at the four-way valve. All of them are certified work.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| A leak in the pipework or joints | The usual cause. Flare joints at either end, brazed connections and the pipe run itself are all candidates, and vibration over years works joints loose. | Common |
| A leak at a coil | Corrosion on the outdoor coil is common in coastal or polluted air. Indoor coils leak less often but are harder and more disruptive to reach. | Occasional |
| A valve or connection at the outdoor unit | The service valves and their caps are a known leak point, and one of the first things a competent engineer will check because it is the cheapest to put right. | Occasional |
| An undercharge from installation | On a system that has never cooled properly rather than one that has deteriorated. Worth raising if the fault has been there since it was fitted. | Occasional |
| A thermistor or a closed stop valve, with the charge intact | The unit infers shortage from temperatures and current rather than measuring gas, so Daikin’s own flow checks the thermistors and the stop valves before concluding refrigerant is short. A stop valve left partly closed after work is the classic false positive. | Occasional |
| Physical damage to the pipe run | Anything from a garden tool to building work. The pipes run outside and through the wall, and they are not as protected as people assume. | Occasional |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£200–£900
Time on site
3 hours
A leak trace and recharge sits at the lower end if the leak is at an accessible joint. A coil replacement or a re-run of pipework costs considerably more, and on an older system it is the point where replacement gets discussed.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Daikin fault codes
- E6Get it checkedThe compressor failed to start. It sits in Daikin’s outdoor unit group alongside the overload and pressure codes, and all of them are certified work.Related: refrigerant circuit
- A5Get it checkedFreeze-up protection or high pressure control. A filthy indoor filter is a legitimate published cause, which makes this the one on the list worth checking yourself.Related: same brand
- U4Get it checkedThe indoor and outdoor units have stopped talking. Daikin’s own cause list starts with the mains supply and the inter-unit cable, so one breaker cycle is worth a try before anyone is called.Related: same brand
- 00Usually simple to fixNot a fault. Daikin publish 00 as NORMAL, and it is also what shows while you are stepping through the diagnostic.Related: same brand
Own a Daikin air conditioner? Save it and its codes come first next time.
Related guides
Common questions about Daikin U0
Can I just get it topped up?
You can, and it will fail again, because the gas did not go anywhere on its own. A sealed circuit that is short has leaked, so a recharge without a leak trace is buying a season. Ask for the leak to be found and fixed, and be cautious of anyone who offers gas without offering that.
Why can I not do this myself?
Because handling the refrigerant requires certification by law. That covers leak detection, recovery, evacuation and recharge — which is the whole of this job. It is not a manufacturer preference or a warranty condition, and the certification exists because releasing these gases has a real environmental cost.
How would I know it is leaking rather than something else?
By the shape of the decline. A leak produces gradual loss of cooling over weeks, longer running times for less effect, sometimes ice on the pipework, and a rising electricity bill because the compressor never stops. A component failure is usually abrupt — working one day and not the next.
Is it dangerous?
Not in the way a gas leak in a boiler is, but it is not nothing. Modern systems increasingly use mildly flammable refrigerant, and a leak in an enclosed space matters. The greater practical risk is running a compressor on an undercharged system, which damages it — so stop using it rather than persevering.
I have a Daikin Altherma heat pump showing U0, not an air conditioner.
Same headline — Daikin publish refrigerant shortage for both — and the same rule that a sealed circuit which is short has leaked and needs a certified repair rather than a top-up. What differs is the machine: an Altherma’s refrigerant lives in the outdoor unit alongside a water circuit, and Daikin’s Altherma checklist ends with a leak test by the installer. The Daikin U0 page in our heat-pumps section is written for it.
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
- Trade body guidance
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.