The appliance is having trouble sensing the flame it has lit. It usually points at the sensing electrode or its earth rather than at the gas side.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Alpha properly.

Get a Gas Safe registered engineer to look at your Alpha E20

Gas Safe Register engineers only. No obligation.

What E20 means

Flame sensing on a domestic boiler works by passing a tiny current through the flame itself — a flame conducts, and the appliance measures that conduction to prove the burner is alight. E20 means that measurement is unreliable: the appliance is seeing a signal, but not a clean or strong enough one to trust. Because the current involved is measured in microamps, this fault is very sensitive to things that would not trouble any other circuit. A film of oxide on the electrode tip, a poor earth on the appliance chassis, or a slightly out-of-position electrode will all degrade the signal. That is genuinely good news: the most common fixes here are cheap. It also explains why E20 often appears intermittently for weeks before becoming permanent, and why it is more common in properties with older or marginal electrical earthing.

What causes it

Causes of the Alpha E20 fault code, most common first
CauseWhat is actually happeningHow likely
Dirty or oxidised sensing electrodeA film builds on the tip and reduces the current the appliance can read. Cleaning is sometimes enough, though replacement is the honest fix once it has started.Common
Poor appliance earthFlame rectification depends on a good earth path. A loose earth at the fused spur or a corroded terminal will produce this exactly.Occasional
Electrode out of positionThe tip has to sit in the flame envelope. If it has been knocked during a previous service, or the bracket has distorted with heat, the signal drops.Occasional
Control board faultThe amplifier stage on the board that reads the ionisation current has degraded. Uncommon, and only diagnosed once the cheap causes are eliminated.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£110–£380

An electrode replacement is £110 to £190 fitted. An earthing fault is usually a call-out charge plus a few pounds of materials. A control board is £300 to £480.

Typical UK prices including parts and labour, updated August 2026. Your quote may differ.

What other owners found

Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.

Written by

Fault Code Check editorial team

Updated

Reviewed by

Technical reviewer

Gas Safe registration to be displayed on appointment

Last reviewed

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Interviews with working engineers

Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.

Read our full verification process