The burner lit correctly and then the flame signal was lost part-way through the cycle. That points somewhere different to a failure to light.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Alpha properly.

What E38 means

Alpha call this loss of flame rectification, and their description is "flame detected but signal lost, ignition retries after fan purge". Two things follow from that. The first is the separation from E01, which is the code people confuse it with: in an E01 the appliance never established a flame at all, while here it did — ignition worked, the flame was proved, the burner ran — and then the signal went. That eliminates a family of causes outright. The electrode evidently fired, and there was gas at the burner at the moment of lighting.

So the question is what changed during the cycle: a gas supply that sags under load rather than being absent, condensate backing up as soon as the appliance starts producing it, a flue recirculating its own products once it warms, or a sensing electrode losing its grip on a marginal signal as the chamber heats and metal moves. The second is a quirk of Alpha's own numbering that will mislead you if you do not know it.

Alpha publish two separate faults under the loss of flame rectification heading — this one, and a different code covering repeated loss of flame signal during operation, which they say can occur when the flue is exposed to high wind. They then note that the second one is "shown as E38 in the fault code history in the INFO menu". So an E38 read off the d9 history is not necessarily the E38 that was on the display, and if yours appears in windy weather on an exposed terminal, the wind explanation is the more likely of the two despite the number.

What causes it

Causes of the Alpha E38 fault code, most common first
CauseWhat is actually happeningHow likely
Gas supply inadequate under loadEnough pressure to light, not enough to sustain full rate. Often an undersized supply pipe or a partly closed meter valve, and it typically shows up worst when a hob is running at the same time.Common
Condensate backing upA partly blocked trap or drain floods the combustion chamber shortly after firing. The pattern is very consistent: it always runs for roughly the same short period before dropping out.Common
Flue recirculation or windCombustion products drawn back into the air intake, or a strong wind across an exposed terminal disturbing the flame. Suspect this if the fault tracks the weather.Occasional
Sensing electrode losing signal when hotA marginal electrode that reads adequately cold and drops below threshold as everything expands.Occasional

What to try yourself

  1. Time it. Note how long the appliance runs before the code appears, over two or three attempts. A consistent interval points at condensate; a random one points at gas supply or wind.

  2. Check whether it fails more readily when another gas appliance is running, such as a hob at full rate. If so, the supply is the likely constraint and that is a job for an engineer with a manometer.

  3. In cold weather, check the external condensate pipe for ice as you would for an ignition lockout, and thaw it with warm water if you find any.

  4. Note whether it is worse on windy days. That is genuinely useful diagnostic information and it is the kind of thing only the household can observe.

  5. Reset no more than twice. Give whoever attends the timing pattern you noted — it will save them a visit.

Get a Gas Safe registered engineer to look at your Alpha E38

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£110–£450

Time on site

20 minutes

A condensate blockage cleared is £80 to £150. An electrode is £110 to £190. Gas supply pipework corrections vary widely, from £150 to well over £600 if a run has to be replaced.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Condensate trap and siphon

COND-TRAP£15–£38Plumbing merchant

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?