Baxi H.03.05 fault codewhat it means and how to fix it

Get it checkedBoilerDotted H.03.05 and H.03.54 on the Baxi 200, 400, 600 and 800 Combi 2, 600 and 800 System 2 and Assure 500 from 2023. The 200/400 Combi (2016) prints H03 54 only. Three-digit Baxis show E385 or 165.Last updated

"Power supply voltage too low" on a Baxi Combi 2: the boiler pauses until the mains recovers and clears itself. Baxi's only remedy is to check the mains voltage; if it recurs, an electrician.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Baxi properly.

What H.03.05 means

H.03.05 is a temporary fault on the Combi 2 and System 2 defined in the manual as "power supply voltage too low" with the single remedy "check the mains voltage". The H means the boiler has stopped for now and will start again by itself: "disappears when the error condition is removed". Its relative, H.03.54, is "temporary flame loss — shutdown due to the power supply voltage being too low", the same sag catching the boiler mid-burn, and the manual's remedy for that runs through the electrode, gas supply and flue checks before ending "check the power supply voltage".

The board watches the mains it is fed because the gas valve, the fan and the ignition all need a supply within range; a brownout that would go unnoticed elsewhere in the house can drop the flame signal or leave a valve half-driven. Like E385 on the three-digit Baxis, this code points away from the boiler. A supply that sags at the boiler terminals is sagging because of a loose or high-resistance connection at the fused spur or the consumer unit, a circuit shared with a heavy appliance whose start-up pulls the voltage down, or an incoming supply that runs low at peak times, which other appliances will show too.

The board is the culprit only when a good supply is being misread, which an engineer establishes by measuring at the boiler terminals under load. No reset is needed or offered; the code goes when the voltage returns. The householder's useful observation is timing — H.03.05 that appears when the shower, oven or a tumble dryer starts is a wiring or loading problem, and that is an electrician's job before it is a heating engineer's.

What causes it

Causes of the Baxi H.03.05 fault code, most common first
CauseWhat is actually happeningHow likely
Loose or high-resistance connectionAt the fused spur, the boiler terminal strip or the consumer unit. Volts are dropped across the poor joint when the boiler draws current, and the board sees a low supply.Common
Shared circuit with a heavy loadA boiler on a ring or spur that also feeds a shower or oven sees a dip each time the load starts. The code comes and goes with household activity.Common
Incoming supply lowEnd-of-line or rural properties where the mains runs low at peak times. Lights dim and other appliances misbehave at the same moments.Occasional
Board misreading a good supplyConcluded only after the supply has been measured at the boiler terminals under load and found normal. A PCB fault, and rare.Rare

What to try yourself

  1. Notice when it happens. If H.03.05 appears as a shower, oven or dryer starts, or in the early evening, the supply is dipping under load and an electrician should check the boiler's circuit and connections.

  2. Nothing to reset. The boiler restarts on its own when the voltage recovers. If it comes with H.03.54 the burner is losing its flame in the dips, and the same cause applies.

  3. If it is frequent and nothing in the house explains it, book a heating engineer to measure the supply at the boiler; a good supply with a persistent code means the board.

Get a Gas Safe registered engineer to look at your Baxi H.03.05

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£0–£400

Time on site

15 minutes

Nothing if the supply recovers. Electrical repair to a spur or connection £100–£250. PCB, if the supply is proven good, £250–£400.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Baxi / Potterton / Main main PCB

£150–£320Authorised Baxi parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process