Ferroli A03 fault codewhat it means and how to fix it

Get it checkedBoilerLast reviewed

High limit protection has operated. Ferroli point at circulation and at the flow sensor position, and both are worth checking.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Ferroli properly.

What A03 means

A03 is high limit protection, a permanent lockout triggered when the appliance reaches a temperature it must never exceed. What is useful about the Ferroli manual here is that it gives two quite different causes rather than the single one most manufacturers list. The first is the expected one: no system circulation, with the manual directing an engineer to check the pump, the radiator valves, and the operation of the internal bypass. The second is more subtle — a flow temperature sensor that is not active or not correctly located. A sensor that has worked loose from its pocket reads the air around it rather than the water, and can report either a wildly wrong temperature or a lagging one that lets the real temperature run away before anything notices. That is a genuinely different repair from a seized pump, and it is why an engineer should verify the sensor is properly seated before condemning anything expensive. The internal bypass is the third thing worth naming, because it is the item most often overlooked.

What causes it

Causes of the Ferroli A03 fault code, most common first
CauseWhat is actually happeningHow likely
No circulation through the appliancePump seized or weak, valves closed, or the system airlocked. The manual directs attention to the pump and the radiator valves first.Common
Air trapped in the primary circuitAn air pocket stops flow completely. Radiators cold at the top and knocking from the appliance both point this way.Common
Flow sensor loose or badly locatedNamed explicitly by Ferroli. A sensor out of its pocket does not read the water, so protection operates late or erratically.Occasional
Internal bypass not operatingThe manual asks for this to be checked. With every thermostatic valve closed and no working bypass, the pump has no path and flow through the exchanger stops.Occasional
Sludge restricting the heat exchangerMagnetite narrowing the waterways. Radiators hot at the top and cold along the bottom is the usual sign.Occasional

What to try yourself

  1. Switch off and let the appliance cool for half an hour. A high limit device will not reset while it is still hot.

  2. Check the pressure reads 1.0 to 1.5 bar cold, and top up through the filling loop if it does not.

  3. Open every thermostatic radiator valve fully. This matters more than usual on a Ferroli given that the manual specifically flags the internal bypass — with all valves shut and a bypass that is not working, there is nowhere for water to go.

  4. Run the heating twenty minutes and feel the radiators top and bottom. Cold at the top is air you can bleed. Cold at the bottom is sludge you cannot.

  5. Reset once. If A03 returns, stop.

    Every reset fires the burner into a heat exchanger that is not being cooled properly. That is the most expensive component in the appliance and this is how it fails.

Get a Gas Safe registered engineer to look at your Ferroli A03

Gas Safe Register engineers only. No obligation.

What it costs to fix

Typical repair cost

£150–£950

Time on site

40 minutes

A pump is £220 to £420 fitted. Reseating or replacing a flow sensor is £110 to £200. A chemical clean with a magnetic filter is £400 to £750.

Typical UK prices including parts and labour, updated August 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Central heating circulating pump

CH-PUMP-15-60£90–£180Plumbing merchant

Price checked 5 August 2026

Magnetic system filter, 22mm

MAG-22£65–£120Plumbing merchant

Price checked 5 August 2026

What other owners found

Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.

Written by

Fault Code Check editorial team

Updated

Reviewed by

Technical reviewer

Gas Safe registration to be displayed on appointment

Last reviewed

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Interviews with working engineers

Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.

Read our full verification process