Skip to content
FaultcodeCheck

Ferroli A05 fault codewhat it means and how to fix it

Get it checkedBoilerLast reviewed

The fan tachometer signal has been missing for an hour or more. The appliance has stopped and needs an engineer.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Ferroli properly.

Get a Gas Safe registered engineer to look at your Ferroli A05

Gas Safe Register engineers only. No obligation.

What A05 means

A05 is the Ferroli fan fault, and the manual defines it precisely: the tachometer signal has been interrupted for one hour or longer. That one-hour qualifier is worth understanding, because it explains the relationship with F15, which is the temporary version of the same fault. A brief interruption produces an F15 that clears itself; an interruption that persists is promoted to A05, a permanent lockout. So an appliance that has been showing an intermittent F15 for weeks and has now locked out on A05 has not developed a new fault — it has finished developing the one it already had. The fan proves that combustion products can be cleared through the flue, and no condensing appliance will open its gas valve without that proof. Ferroli direct a check of the wiring as well as the fan itself, and that ordering is sensible: a tachometer signal can be lost to a corroded connector while the fan spins perfectly well.

What causes it

Causes of the Ferroli A05 fault code, most common first
CauseWhat is actually happeningHow likely
Fan bearings wornThe dominant cause beyond about eight years of service, and usually preceded by months of grumbling on start-up.Common
Wiring or connector fault losing the tachometer signalFerroli list checking the wiring before the fan. The fan may be turning normally while the board hears nothing from it.Occasional
Flue obstructedA nest or debris in the terminal changes the load on the fan and therefore its speed, throwing the check even on a healthy fan.Occasional
Control board input faultThe board cannot read a good signal. Considered only once the fan and its wiring have been eliminated.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£180–£420

A fan assembly is typically £280 to £420 fitted. A wiring repair or flue clearance is a call-out charge of £80 to £140.

Typical UK prices including parts and labour, updated August 2026. Your quote may differ.

What other owners found

Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.

Written by

Fault Code Check editorial team

Updated

Reviewed by

Technical reviewer

Gas Safe registration to be displayed on appointment

Last reviewed

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Interviews with working engineers

Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.

Read our full verification process