Ferroli A05 fault codewhat it means and how to fix it
The fan tachometer signal has been missing for an hour or more. The appliance has stopped and needs an engineer.
Take care
Get a Gas Safe registered engineer to look at your Ferroli A05
Gas Safe Register engineers only. No obligation.
What A05 means
A05 is the Ferroli fan fault, and the manual defines it precisely: the tachometer signal has been interrupted for one hour or longer. That one-hour qualifier is worth understanding, because it explains the relationship with F15, which is the temporary version of the same fault. A brief interruption produces an F15 that clears itself; an interruption that persists is promoted to A05, a permanent lockout. So an appliance that has been showing an intermittent F15 for weeks and has now locked out on A05 has not developed a new fault — it has finished developing the one it already had. The fan proves that combustion products can be cleared through the flue, and no condensing appliance will open its gas valve without that proof. Ferroli direct a check of the wiring as well as the fan itself, and that ordering is sensible: a tachometer signal can be lost to a corroded connector while the fan spins perfectly well.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Fan bearings worn | The dominant cause beyond about eight years of service, and usually preceded by months of grumbling on start-up. | Common |
| Wiring or connector fault losing the tachometer signal | Ferroli list checking the wiring before the fan. The fan may be turning normally while the board hears nothing from it. | Occasional |
| Flue obstructed | A nest or debris in the terminal changes the load on the fan and therefore its speed, throwing the check even on a healthy fan. | Occasional |
| Control board input fault | The board cannot read a good signal. Considered only once the fan and its wiring have been eliminated. | Rare |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£180–£420
A fan assembly is typically £280 to £420 fitted. A wiring repair or flue clearance is a call-out charge of £80 to £140.
Typical UK prices including parts and labour, updated August 2026. Your quote may differ.
What other owners found
Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.
Related Ferroli fault codes
- F07Get it checkedFlue gas temperature has stayed above 95°C for more than two minutes. Three of these in a day becomes a permanent A04 lockout.Related: fan and flue
- C6 224Get it checkedThe fan is not reaching the speed the boiler asked for, so combustion cannot be confirmed as safe and the burner has been prevented from firing.Related: fan and flue
- E16Get it checkedThe control board cannot confirm the fan is running at the speed it asked for, so it will not let the burner light. This one needs an engineer.Related: fan and flue
- F.32Get it checkedThe fan is not running at the speed the boiler expects, so combustion cannot be verified as safe and the boiler has locked out.Related: fan and flue
- E160Get it checkedThe fan is not running at the speed the appliance expects. Baxi direct engineers to check the fan and its cable, in that order.Related: fan and flue
- F3Get it checkedThe fan is not running at the speed the boiler expects, so it cannot confirm the flue is clearing and has stopped the burner firing.Related: fan and flue
Related guides
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
- Interviews with working engineers
Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.