Ferroli F07 fault codewhat it means and how to fix it
Flue gas temperature has stayed above 95°C for more than two minutes. Three of these in a day becomes a permanent A04 lockout.
Take care
Get a Gas Safe registered engineer to look at your Ferroli F07
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
What F07 means
On the Optimax range Ferroli define F07 precisely: the exhaust gas temperature has become higher than 95°C for two minutes. Read the range qualifier, because it is load-bearing — F07 means something else entirely on other Ferroli platforms, an air pressure switch fault on the i25 and i29 and a PCB parameter fault on the FERcondens, and this page describes only the Optimax version.
As an F code it clears itself once the temperature falls back, which is why it can occur repeatedly without anyone noticing. The escalation is the part to pay attention to. Three F07 events within twenty-four hours are promoted to A04, a flue gas fault that is a permanent lockout. So an appliance that suddenly stops on A04 has almost always been quietly logging F07 for some time first. A condensing boiler is designed to send comparatively cool gas up the flue, because capturing that heat is the whole basis of its efficiency.
Persistently hot flue gas means heat is not passing into the water where it belongs — usually because scale or sludge is coating the heat exchanger, or because circulation is too slow to carry heat away. It also matters for the flue itself: plastic flue systems are rated for normal condensing temperatures, and sustained overtemperature is outside what they are built for.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Heat exchanger scaled or fouled | A deposit layer insulates the metal from the water so heat leaves through the flue instead. Progressive over months and common in hard water areas. | Common |
| Poor circulation | Water moving too slowly picks up less heat per pass. Shares most of its causes with the high limit fault. | Common |
| Exchanger probe fault | It is the exchanger probe that Ferroli have watching this, and they list a fault with it separately as F13. A probe that has drifted rather than failed outright can produce a false F07. | Occasional |
| Appliance overfiring | Gas rate set too high, usually after earlier work. Confirmed with a flue gas analyser, not by inspection. | Rare |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£140–£1,100
A flue sensor is £140 to £220 fitted. A chemical clean with a magnetic filter is £400 to £750. A heat exchanger descale is £250 to £450, and replacement £700 to £1,100.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Magnetic system filter, 22mm
MAG-22£65–£120Plumbing merchant
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Ferroli fault codes
- A05Get it checkedThe fan tachometer signal has been missing for an hour or more. The appliance has stopped and needs an engineer.Related: fan and flue
- A01Get it checkedThe burner failed to light and the appliance has locked out. Ferroli list a blocked siphon as a cause, which is worth checking early.Related: same brand
- F37Usually simple to fixSystem water pressure is outside the correct range. Because this is an F code it clears by itself once you top the system back up.Related: same brand
- A03Get it checkedHigh limit protection has operated. Ferroli point at circulation and at the flow sensor position, and both are worth checking.Related: same brand
- A02Stop — call an engineerA flame is being detected while the burner should be off. Switch the appliance off and get a Gas Safe engineer to it.Related: same brand
Own a Ferroli boiler? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.