Skip to content
FaultcodeCheck

Ferroli F07 fault codewhat it means and how to fix it

Get it checkedBoilerLast reviewed

Flue gas temperature has stayed above 95°C for more than two minutes. Three of these in a day becomes a permanent A04 lockout.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Ferroli properly.

Get a Gas Safe registered engineer to look at your Ferroli F07

Gas Safe Register engineers only. No obligation.

What F07 means

Ferroli define F07 precisely: the exhaust gas temperature has exceeded 95°C for two minutes or more. As an F code it clears itself once the temperature falls back, which is why it can occur repeatedly without anyone noticing. The escalation is the part to pay attention to. Three F07 events within twenty-four hours are promoted to A04, a flue gas fault that is a permanent lockout. So an appliance that suddenly stops on A04 has almost always been quietly logging F07 for some time first. A condensing boiler is designed to send comparatively cool gas up the flue, because capturing that heat is the whole basis of its efficiency. Persistently hot flue gas means heat is not passing into the water where it belongs — usually because scale or sludge is coating the heat exchanger, or because circulation is too slow to carry heat away. It also matters for the flue itself: plastic flue systems are rated for normal condensing temperatures, and sustained overtemperature is outside what they are built for.

What causes it

Causes of the Ferroli F07 fault code, most common first
CauseWhat is actually happeningHow likely
Heat exchanger scaled or fouledA deposit layer insulates the metal from the water so heat leaves through the flue instead. Progressive over months and common in hard water areas.Common
Poor circulationWater moving too slowly picks up less heat per pass. Shares most of its causes with the high limit fault.Common
Flue sensor faultFerroli list F45 and F46 separately for a damaged or disconnected flue sensor, but a drifting sensor can produce a false F07 too.Occasional
Appliance overfiringGas rate set too high, usually after earlier work. Confirmed with a flue gas analyser, not by inspection.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£140–£1,100

A flue sensor is £140 to £220 fitted. A chemical clean with a magnetic filter is £400 to £750. A heat exchanger descale is £250 to £450, and replacement £700 to £1,100.

Typical UK prices including parts and labour, updated August 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Magnetic system filter, 22mm

MAG-22£65–£120Plumbing merchant

Price checked 5 August 2026

What other owners found

Nobody has shared what worked for them on this code yet. If you have had it, you would be the first — and it genuinely helps the next person.

Written by

Fault Code Check editorial team

Updated

Reviewed by

Technical reviewer

Gas Safe registration to be displayed on appointment

Last reviewed

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Interviews with working engineers

Checked by Technical reviewer (Gas Safe registration to be displayed on appointment) on 5 August 2026.

Read our full verification process