Glow-worm F.10 fault codewhat it means and how to fix it
F.10 on an Energy, Ultimate, Compact or two-digit Ultracom2 means the flow sensor has shorted. F10 on an Ultracom, Flexicom or Ultrapower names the return thermistor instead.
Take care
Get a Gas Safe registered engineer to look at your Glow-worm F.10
We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.
Which display are you looking at?
The right answer depends on what you can see. Pick the one that matches.
Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.
F.10 with a stop, or F10 on an Ultracom2, Betacom 24a/28a or Betacom2
Flow temperature sensor shorted, or its harness. The boiler will not run until it is fixed.
Book a Gas Safe registered engineer. Tell them which range it is so they bring the right thermistor.
F10 on an Ultracom hxi, cxi or sxi, a Flexicom or an Ultrapower, or 10 on a CI display
Glow-worm's table says "central return flow thermistor" — the return sensor, not the flow.
Book a Gas Safe registered engineer and say it is the older range; the part is the return thermistor.
What F.10 means
Two generations, two sensors. With a stop — F.10 — on an Energy, Ultimate, Easicom or Compact the code is "Short circuit: Flow temperature sensor", the mirror of F.00, and Glow-worm's manuals give the causes as "NTC sensor defective, short circuit in the cable harness, cable/housing". The two-digit Ultracom2, Betacom 24a/28a and Betacom2 keep that meaning as F10, "flow heating temperature sensor fault — sensor short-circuit".
But on an Ultracom hxi, cxi, sxi, a Flexicom or an Ultrapower, the trade table lists F10 as "Central return flow thermistor" — a fault on the return sensor, the one on the pipe coming back to the boiler — and the 24CI/18SI manual has 10 as "central heating return NTC fault".
So the same two digits send an engineer to opposite ends of the heat exchanger depending on the age of the boiler. The work is the same kind either way: meter the thermistor the code actually names, inspect its lead for chafing on the casing, replace whichever has failed, and reset. Glow-worm's homeowner page carries F.10 with the single instruction to call an engineer, and none of the older user guides gives a householder action for F10 at all.
What causes it
| Cause | What is actually happening | How likely |
|---|---|---|
| Flow thermistor failed short — F.xx and two-digit ranges | The bead fails to a low resistance and the board reads a temperature far above anything the water could reach. Glow-worm's "NTC sensor defective". Confirmed with a meter against the resistance table and replaced. | Common |
| Harness or cable shorted | Glow-worm name "short circuit in the cable harness, cable/housing". A lead rubbed through where it crosses the case, or trapped by the front panel at the last service, touches earth and shorts the sensor circuit. | Common |
| Return thermistor fault — Ultracom, Flexicom, Ultrapower and CI | On the F1-to-F77 boilers F10 is the return sensor, not the flow. The same checks apply, on the other pipe. An engineer who assumes the current meaning will meter the wrong part. | Common |
Can you fix it yourself?
Stop — this needs an engineer
What it costs to fix
Typical repair cost
£80–£160
Time on site
45 minutes
Flow or return thermistor fitted £80–£160. A harness that has chafed through is mostly labour and sits at the top of that range.
Typical UK prices including parts and labour, updated September 2026. Your quote may differ.
Parts you may need
We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.
Glow-worm flow or return temperature sensor (clip-on NTC)
£12–£35Authorised Glow-worm parts distributor
Price checked 28 September 2026
Own this appliance and had this code? . Nothing is published until a person has read it.
Related Glow-worm fault codes
- F.00Get it checkedThe flow temperature sensor circuit is open — plug off, wire broken or thermistor failed — so the boiler has no flow temperature and will not run. Engineer's code on every range.Related: temperature sensors
- F.11Get it checkedOn Energy, Ultimate, Compact and the two-digit Ultracom2 and Betacom, F.11 is a shorted return sensor. On an Ultracom hxi or cxi, F11 is a main board connection fault. Engineer either way.Related: temperature sensors
- F.72Get it checkedThe flow and return sensors disagree by an amount the board will not accept — one sensor is wrong, or on Glow-worm's own account water is not circulating. An installer's call in the first instance.Related: temperature sensors
- F.71Get it checkedThe flow sensor is still connected but its reading has stopped changing while the burner runs — usually because it has come off the pipe. An engineer reseats or replaces it.Related: temperature sensors
- F.13Get it checkedOn a system or regular boiler with a cylinder sensor, F.13 means that sensor has shorted. F13 on an Ultracom, Flexicom or CI-range boiler points at the main board instead. Engineer's code.Related: temperature sensors
- F.84Get it checkedThe return is reading hotter than the flow — the two sensors are on each other's pipes, or the pipework is crossed. Glow-worm send this one to the installer, because it is nearly always workmanship.Related: temperature sensors
Own a Glow-worm boiler? Save it and its codes come first next time.
Related guides
Technical review
Not reviewed by an engineer
No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.
Sources and how we verified this
We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.
- Manufacturer technical and service documentation
- Manufacturer support portal
This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.