On a system or regular boiler with a cylinder sensor, F.13 means that sensor has shorted. F13 on an Ultracom, Flexicom or CI-range boiler points at the main board instead. Engineer's code.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F.13

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

Which boiler and display?

The right answer depends on what you can see. Pick the one that matches.

Choose the option on the left that matches what your appliance is doing, and the answer for that case appears here.

F.13 with a stop on a system or regular boiler with a hot water cylinder

Cylinder temperature sensor shorted, or its cable.

Book a Gas Safe registered engineer. Hot water may still be available on a timer while heating waits.

F.13 with a stop on a combi

A combi has no cylinder sensor. The board is configured wrongly or a harness is shorted.

Book a Gas Safe registered engineer to check the Device Specific Number and the harness.

F13 without a stop on an Ultracom, Flexicom, Xtramax or 13 on a CI display

Glow-worm's table names the main PCB, not a sensor.

Book a Gas Safe registered engineer and say which range, so they expect an electronics fault.

What F.13 means

F.13 only has a sensor to point at on a boiler that heats a cylinder. On an Energy, Ultimate or Compact system or regular model wired to a cylinder thermistor, Glow-worm define it as "Short circuit: Temperature sensor for the domestic hot water cylinder", causes "NTC sensor defective, short circuit in the cable harness, cable/housing".

The Energy7 manual adds that F.12 and F.91 flag the same cylinder sensor short on that range, and the Compact manual finishes its F.13 row with "set the correct Device Specific Number" — the board's configuration code — because a combi told it has a cylinder will report a sensor it was never given. On the Ultracom cxi, hxi and sxi, the Flexicom and the Xtramax HE, F13 is "PCB memory or sensing fault"; on the earlier cxi, sxi, SI, CI and CI Plus it is "main PCB connection fault", and the 24CI/18SI manual lists 13 simply as "main board fault".

So the two-digit F13 on the older ranges is an electronics code, not a sensor code, and the cost of the two readings is very different: a cylinder thermistor is one of the cheapest parts on the installation, a main board one of the dearest. The two-digit Ultracom2 and Betacom tables carry no 13 at all.

What causes it

Causes of the Glow-worm F.13 fault code, most common first
CauseWhat is actually happeningHow likely
Cylinder thermistor shorted — system and regular boilersThe sensor sits in a pocket on the hot water cylinder, often the far end of the longest cable on the installation. A failed bead or a cable trapped behind the airing cupboard door both read as a short at the boiler.Common
Wrong Device Specific NumberThe Compact manual's last measure for F.13. A board configured for a system boiler on a combi, or after a PCB swap without the number being set, expects a cylinder sensor that does not exist.Occasional
Main board fault — Ultracom, Flexicom, Xtramax and CIOn those ranges F13 means the main PCB, its memory or its connections. Glow-worm's trade tables give no cause beyond the board; an engineer checks its plugs and supply before replacing it.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£350

Time on site

1 hour

Cylinder thermistor fitted £80–£160. A configuration correction is a call-out fee. A main board on an Ultracom or Flexicom £250–£350.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Glow-worm flow or return temperature sensor (clip-on NTC)

£12–£35Authorised Glow-worm parts distributor

Price checked 28 September 2026

Glow-worm main PCB

£150–£320Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?