Glow-worm F.71 fault codewhat it means and how to fix it

Get it checkedBoilerF.71 on Energy, Ultimate, Easicom, Betacom3/4 and Compact · F71 on Ultracom2, Betacom 24a/28a and Betacom2 · no 71 on Ultracom, Flexicom or Ultrapower; the CI range shows 19 for a flow NTC not on the pipeLast updated

The flow sensor is still connected but its reading has stopped changing while the burner runs — usually because it has come off the pipe. An engineer reseats or replaces it.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F.71

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.71 means

F.71 is the code for a flow sensor that passes every electrical test and still lies. Glow-worm's Energy7 and Ultimate3 manuals describe it as the "flow temperature sensor signalling constant value" with two causes: the sensor is "incorrectly positioned on flow pipe" or it is "defective". The Compact manual's three measures are, in order, check the positioning, check the positioning, then replace the sensor — which tells you where Glow-worm expect the fault to be.

The two-digit Ultracom2, Betacom 24a/28a and Betacom2 list F71 as "flow heating temperature sensor fault — unclipped or defective (no temperature variation)", and their remedy is the plainest sentence in the manual: "make sure that the sensor is clipped to the tube". The thermistor is a clip-on part, and a clip disturbed during a service or a heat exchanger change leaves it hanging in the casing air, reading room temperature while the water behind it climbs.

The board sees the burner firing and the number not moving and stops before the overheat protection has to. The Ultracom, Flexicom and Ultrapower tables carry no 71; on the CI range the nearest code is 19, "central heating NTC not connected to pipe", which is the same fault under a different number.

What causes it

Causes of the Glow-worm F.71 fault code, most common first
CauseWhat is actually happeningHow likely
Sensor clip off the pipeGlow-worm's first and second measures are both "check the positioning". The clip springs off during work on the boiler and the sensor reads the casing air, which does not change when the burner lights.Common
Sensor refitted on the wrong pipeAfter a heat exchanger or pipe change the flow sensor can end up on a pipe that does not warm with the burner. The reading is real, just not of the flow.Occasional
Thermistor drifted to a fixed value"Flow temperature sensor defective" — a bead that has aged into a near-constant resistance. Proven by warming the sensor and watching the reading fail to follow, and replaced.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£160

Time on site

30 minutes

Often no part at all — a sensor clipped back on within a call-out fee of £80–£130. A new thermistor £100–£160 fitted.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Glow-worm flow or return temperature sensor (clip-on NTC)

£12–£35Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Common questions about Glow-worm F.71

The boiler fires, runs a minute and shows F.71. Why?

That is the fault exactly. The board expects the flow reading to rise as the burner runs; when it does not, it assumes the sensor is not seeing the water and stops to protect the heat exchanger.

Did the last service cause it?

It is the most common explanation. The flow sensor clip is easy to disturb, and F.71 within days of a service or a repair is worth mentioning to whoever did the work.

Is this the same as F.83?

Related. F.83 is the board seeing no temperature change on either sensor and blaming low water; F.71 is the flow sensor alone signalling a constant value. Both often trace to a sensor off its pipe.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.