Glow-worm F.67 fault codewhat it means and how to fix it

Get it checkedBoilerF.67 on Energy, Ultimate, Easicom, Betacom3/4 and Compact (Compact adds the flue gas route) · F67 on Ultracom2, Betacom 24a/28a and Betacom2 · not in the Ultracom, Flexicom or CI tablesLast updated

F.67 means the flame signal the board's ASIC reports is implausible — the electronics disagree with themselves about whether there is a flame. The Compact adds the flue route as a cause.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F.67

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.67 means

Glow-worm's title for F.67 on the Energy and Ultimate is a mouthful — "value sent back by ASIC is incorrect (flame signal)" — and its two causes are "implausible flame signal, electronics defective". The ASIC is the chip on the main board that monitors the ionisation current through the flame; F.67 is raised when what it reports cannot be reconciled with what the rest of the board expects, which is a different fault from F.27 (flame seen when there should be none) or F.68 (a real but unstable flame).

The Compact manual is more generous with causes: "implausible flame signal — check the flame signal", "PCB defective — replace the PCB", and then "fault in the flue gas route — check the entire flue gas route", because recirculating flue gas can disturb the ionisation current enough to make the signal nonsensical. The two-digit Ultracom2, Betacom 24a/28a and Betacom2 list F67 as "flame signal fault in the main board" with the shared F61-to-F67 measures — connections, board, DSN, reset. There is no 67 in the older Ultracom, Flexicom or CI tables.

An engineer checks the flame sensing electrode and its lead, and on a Compact the flue, before deciding the board is at fault; a poor earth on the boiler chassis is a known way to corrupt the ionisation reading and is cheaper to fix than anything on the board. Glow-worm give no householder step.

What causes it

Causes of the Glow-worm F.67 fault code, most common first
CauseWhat is actually happeningHow likely
Flame sensing circuit giving an implausible readingGlow-worm's first cause. The electrode, its lead or the boiler's earth connection produce an ionisation current the board cannot interpret. Checked and cleaned or corrected before the board is suspected.Common
Flue gas recirculating — CompactThe Compact manual's third cause: a fault in the flue gas route. Products of combustion drawn back into the air intake disturb the flame and its signal.Occasional
Main board ASIC failed"Electronics defective." The flame monitoring chip itself; the board is replaced and configured with the correct Device Specific Number.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£100–£380

Time on site

1 hour

Electrode, lead or earth corrected £100–£180. A main PCB £250–£380 fitted.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Glow-worm ignition and flame-sensing electrode

£18–£45Authorised Glow-worm parts distributor

Price checked 28 September 2026

Glow-worm main PCB

£150–£320Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation
  • Manufacturer support portal

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?