Skip to content
FaultcodeCheck

Glow-worm F.89 fault codewhat it means and how to fix it

Get it checkedBoilerEnergy, Ultimate, Easicom, Betacom3/4 and Compact only · not in the Ultracom2, Betacom two-digit or any older tableLast updated

F.89 means the board cannot see the pump it expects — unplugged, wired wrongly, the wrong pump fitted or a short in its harness. Current ranges only, and it usually follows a pump change.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F.89

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.89 means

F.89 is one of the codes added with the current generation of Glow-worm boards, and it is a wiring code rather than a pumping one. The Energy7 and Ultimate3 manuals define it as "Fault: pump" with the causes "pump not connected or it is connected incorrectly, incorrect pump connected, short circuit in the cable harness". The Compact manual gives the same causes as measures and adds the one that matters most in practice: "check whether the pump that is connected is the one that is recommended for the product".

The pumps on these boilers are modulating units that report back to the board over a control lead as well as taking power from it; a pump from another model, or a replacement wired with the power lead but not the signal lead, runs perfectly well and still produces F.89 because the board cannot hear it. It is not in the two-digit Ultracom2 or Betacom tables, nor any older list — those boards drive a simple pump and report circulation problems through F.23, F.24 and F.75 instead.

So F.89 almost always dates from a pump replacement, and the person to call is whoever did it. A pump that is connected and recognised but not moving water shows up as one of the circulation codes, not this one; if the boiler is quiet where the pump should hum and F.89 is on the display, the board and the pump have simply not been introduced. No user guide gives a householder step.

What causes it

Causes of the Glow-worm F.89 fault code, most common first
CauseWhat is actually happeningHow likely
Pump signal lead not connected after a replacementGlow-worm's "not connected or connected incorrectly". The pump takes power on one plug and talks to the board on another; a replacement fitted with only the first runs but is invisible to the board.Common
Wrong pump fittedThe Compact manual's "check whether the pump that is connected is the one recommended". A pump from another range or a generic unit does not speak the board's protocol.Occasional
Short in the pump harnessA lead chafed on the pump body or trapped by the casing. Rarer than the two above and found with a meter.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£150

Time on site

45 minutes

A wiring correction £80–£150. If the wrong pump was fitted, replacing it with the correct one is the installer's to put right.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Central heating circulating pump

CH-PUMP-15-60£90–£180Plumbing merchant

Price checked 28 September 2026

Glow-worm main PCB

£150–£320Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?