Glow-worm F17 fault codewhat it means and how to fix it

Get it checkedBoilercxi, sxi, SI, CI and CI Plus only (17 on the 24CI display) · not on Ultracom, Flexicom, Ultracom2, Betacom or the F.xx rangesLast updated

F17 on a cxi, sxi, SI, CI or CI Plus means the mains supply to the boiler has dropped below 170 volts. The fault is usually the house wiring or the supply, not the boiler.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F17

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F17 means

F17 is a Hepworth-era code that the later Glow-worm lists dropped. The trade tables for the cxi, sxi, SI, CI and CI Plus give it as "power supply is less than 170v", and the 24CI/18SI manual lists 17 as "power supply <170V". The board measures its own incoming mains and refuses to run the ignition and the fan when the voltage is too low to do so reliably; 170 volts is a long way below the 230 the supply should deliver, so a genuine F17 means something is badly wrong upstream of the boiler rather than inside it.

A loose neutral at the fused spur, a spur shared with a high-draw appliance, a long extension of undersized cable to a boiler in an outbuilding, or a supply fault in the street will all do it, and the code may come and go with the time of day. A board whose voltage measurement has drifted is the other possibility, and the way to separate the two is a meter on the boiler's supply while the code is showing.

The Ultracom, Flexicom and Ultrapower have no F17, nor do the two-digit Ultracom2 and Betacom boards or the current F.xx ranges, which stop on low voltage without a dedicated code. There is nothing in Glow-worm's guides for a householder to do beyond noticing whether other things in the house dim or flicker at the same time, which is worth telling whoever comes — and if the whole house is affected, the electricity supplier rather than a boiler engineer is the call.

What causes it

Causes of the Glow-worm F17 fault code, most common first
CauseWhat is actually happeningHow likely
Poor connection at the fused spur or plugA loose neutral or a corroded terminal drops the voltage under load and reads low at the boiler while the rest of the house is fine. The commonest finding and the cheapest.Common
Supply genuinely lowA fault in the street or a heavily loaded local network can pull the whole house below what the boiler will accept, usually at peak times. Lights dim as the code appears.Occasional
Board measuring wronglyA main board whose supply monitoring has drifted shows F17 on a healthy 230 volts. Confirmed by metering the supply while the code is displayed.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£300

Time on site

45 minutes

A spur or terminal remade £80–£150 by an electrician. A main board on a CI-era boiler £200–£300 where still available. A supply fault in the street costs nothing.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Glow-worm main PCB

£150–£320Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer support portal
  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?