Skip to content
FaultcodeCheck

Glow-worm F18 fault codewhat it means and how to fix it

Get it checkedBoilercxi, sxi, SI, CI and CI Plus only (18 on the 24CI display) · not on Ultracom, Flexicom, Ultracom2, Betacom or the F.xx rangesLast updated

F18 on a cxi, sxi, SI, CI or CI Plus is a fault in the user interface — the display and button board itself, where F12 is its link to the main board.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Glow-worm properly.

Get a Gas Safe registered engineer to look at your Glow-worm F18

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F18 means

The Hepworth-era Glow-worm boilers report their control panel in three codes. F11 is "main board connection fault" and F12 the "connection fault between main PCB and display PCB" — the lead between the two boards. F18 is the third: "user interface fault" in the trade tables for the cxi, sxi, SI, CI and CI Plus, and "local user interface fault" in the 24CI/18SI manual, meaning the display and button board itself has failed its checks rather than lost contact with the main board. The same manual also lists 20 as "user interface not compatible with boiler", which is the code for a replacement panel of the wrong type.

In practice an F18 panel shows odd segments, refuses buttons, or shows the code intermittently as the board warms; the 24CI manual's replacement procedure has the fascia unclipped and hinged forward, the connections disconnected and the board swapped, and it is not a householder's job.

The Ultracom, Flexicom and Ultrapower have no F18, the two-digit Ultracom2 and Betacom boards report a display problem as Err, and the current F.xx ranges have no interface code at all. Whether a twenty-year-old user interface board is still available is the question the engineer will answer before ordering, and it is fair to ask about the cost of the alternative at the same time.

What causes it

Causes of the Glow-worm F18 fault code, most common first
CauseWhat is actually happeningHow likely
User interface board failedGlow-worm's only cause. The display and button board has failed its self-check, often after years of heat cycling behind the fascia. Replaced as a board.Common
Moisture or a knocked connector on the panelA drip from a joint above the fascia, or a connector disturbed when the panel was hinged open, can fail the board's check without the board being dead. Checked before ordering.Occasional
Wrong replacement panelThe 24CI manual lists a separate code, 20, for a user interface not compatible with the boiler; a replacement of the wrong type can also show as a general interface fault.Rare

Can you fix it yourself?

What it costs to fix

Typical repair cost

£150–£300

Time on site

1 hour

A user interface board on a CI-era boiler £150–£300 fitted, where still available.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Glow-worm main PCB

£150–£320Authorised Glow-worm parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Own a Glow-worm boiler? Save it and its codes come first next time.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer support portal
  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?