Ideal Pump Dry Run fault codewhat it means and how to fix it

Get it checkedBoilerLogic+ and Logic Max Combi2 and System2 (2023 on); not on the Heat2, which has no pumpLast updated

A Logic+ or Logic Max text screen saying the pump is turning with no water to move. Ideal's steps are the filling ones: boiler off and cold, fill to 1.0 bar, bleed the radiators, refill.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Ideal properly.

What Pump Dry Run means

Pump Dry Run appears in the 2023 user guides for the Logic+ and Logic Max Combi2 and System2, the text-screen versions of the boiler the plain Logic Combi2 reports in three-character codes. The modulating pump on those boilers can tell when its impeller is spinning in air rather than water and says so, and Ideal give the householder the same three steps they give for Low Water Pressure and No Water Flow: with the boiler off and the system cold, fill to 1.0 bar; bleed the radiators and refill to 1.0 bar; if the fault persists, contact the installer.

The screen offers only a Menu key, no Restart, which is Ideal's way of saying it clears itself once the pump is wet again. The heat-only Heat2 guides do not list it because that boiler has no pump of its own.

What Ideal do not publish is which of the Logic Combi2's numeric pump codes — F 12 for a blocked rotor, F 13, F 15 and F 17 for pump faults — this message corresponds to, if any, so it stands as its own page rather than being folded into one of them.

What causes it

Causes of the Ideal Pump Dry Run fault code, most common first
CauseWhat is actually happeningHow likely
System pressure lostThe commonest way a pump ends up in air. A slow leak or a discharged expansion vessel lets the level fall until the pump chamber, at the top of the boiler, empties first.Common
Air trapped after fillingA system refilled quickly leaves a pocket in the pump housing that the pressure gauge cannot see. Ideal's bleed-and-refill step exists for exactly this.Common
Pump reporting wronglyA pump that is wet and still says it is dry has a fault of its own, and that is the installer's end of Ideal's three steps.Rare

What to try yourself

  1. Switch the boiler off and let it go cold. Read the pressure gauge: if it is below 1.0 bar, fill using the filling loop until it reads 1.0 bar, then close the loop. Ideal's user guide gives these as the first steps.

  2. Bleed every radiator, starting downstairs, then refill to 1.0 bar. Bleeding drops the pressure, and a pump housing full of air will only clear once the system is properly vented and back at pressure.

  3. Switch on and call for heat. The message has no Restart key because it clears on its own once the pump sees water. If it stays, or comes back within days, contact the installer — the pump may be at fault, or the system is losing water.

Get a Gas Safe registered engineer to look at your Ideal Pump Dry Run

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What it costs to fix

Typical repair cost

£0–£380

Time on site

30 minutes

Nothing if filling and bleeding cures it. Finding a leak that keeps emptying the system is £80–£150 upwards depending on where it is. A replacement modulating pump £220–£380 fitted.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Expansion vessel (8 litre, sealed system)

EV-8L£35–£85Plumbing merchant

Price checked 28 September 2026

Central heating circulating pump

CH-PUMP-15-60£90–£180Plumbing merchant

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Ideal Pump Dry Run

Why does the screen have no Restart button for this?

Because it is not a lockout. Ideal only offer Restart on faults that latch, like Ignition Lockout. Pump Dry Run is a condition the boiler reports while it lasts and drops when the pump is wet again, so the fix is filling, not pressing.

Is this the same as No Water Flow?

They overlap but are not the same. No Water Flow means the boiler cannot detect water moving; Pump Dry Run means the pump itself has detected it is running in air. Ideal give the same filling steps for both, and both point at pressure and air before anything else.

Which code is this on a plain Logic Combi2?

Ideal do not say. The Combi2 has F 12 for a blocked rotor and F 13, F 15 and F 17 as pump faults, but no published mapping from Pump Dry Run to any of them, so this page does not claim one.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?