Vaillant F.33 fault codewhat it means and how to fix it

Stop — call an engineerBoilerecoTEC exclusive (both editions), 48–64 kW ecoTEC plus VU 446 and 606/5-5, turboMAX plus 837 and 637 only. Not in the ecoTEC plus ..6/5-5, pro, ecoFIT, ecoTEC sustain, 2005–2012 ecoTEC or CS/1-5 tables.Last updated

An air pressure switch fault: the boiler cannot prove the fan is moving air through the flue. Vaillant check the flue route first, so treat it as a flue fault until proved otherwise.

Get a Gas Safe registered engineer to look at your Vaillant F.33

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.33 means

F.33 belongs to the Vaillant boilers that carry an air pressure switch or sensor to prove air flow, which is not all of them. The ecoTEC exclusive prints it as "pressure switch" or, in the later edition, "air/flue gas pressure implausible", with a check list that runs through the cable harness, the vacuum hose for blockage, the supply air and flue gas route for blockage, the panel being the correct type, the flue pipe length, the air pressure sensor, the D.132 multiple-flue setting, the pressure switch and the fan. The 48–64 kW ecoTEC plus puts it in two lines: "air/flue pipe blocked — check the entire air/flue pipe; defective air pressure switch — replace".

On the turboMAX plus 837 and 637 the same number is the older switch: "no switching signal from the air pressure switch — check air pressure switch, fan, fan supply or flue", with the note that a replacement sensor must have a switching point of 105/90 Pa. The ecoTEC plus ..6/5-5, pro, ecoFIT and ecoTEC sustain tables have no F.33 row, because those boilers prove the fan by its speed signal (F.32) rather than a pressure switch.

What matters to a householder is the order of Vaillant's list: the flue comes before the switch. A blocked flue or air intake is one of the few boiler faults that can put combustion products where they should not be, and Vaillant's consumer page adds "blockage in the flue or condensate discharge" among its causes. This page carries no steps for that reason.

What causes it

Causes of the Vaillant F.33 fault code, most common first
CauseWhat is actually happeningHow likely
Air or flue route blocked or restrictedVaillant's "supply air/flue gas route (blockage)" and the 48–64 kW table's first cause. Debris or a nest at the terminal, a crushed or displaced flue section, or ice at the terminal in winter.Common
Vacuum hose blocked or detachedThe small tube that carries pressure to the switch or sensor. Blocked with condensate or debris it reports no flow with the fan running normally.Common
Air pressure switch or sensor failedThe switch itself. Vaillant list it after the flue checks, and the turboMAX plus specifies the 105/90 Pa switching point for its replacement.Occasional
Fan, wrong panel or flue length outside the settingThe rest of the exclusive list: a fan not reaching speed, a front panel of the wrong type disturbing the air path, a flue longer than the D.132 configuration allows.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£90–£320

Time on site

1 hour

Clearing a flue terminal or replacing a hose is £90 to £160. An air pressure switch is £120 to £200 fitted; a fan £230 to £320. Flue rebuilding is priced on inspection.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Vaillant ecoTEC fan assembly

0020039840£120–£230Authorised Vaillant parts distributor

Price checked 28 September 2026

Vaillant wiring harness (plug-and-cable set to a sensor or actuator)

£20–£65Authorised Vaillant parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Vaillant F.33

Can I just reset it and see?

One reset does no harm, but if F.33 returns stop there. The boiler is refusing to fire because it cannot prove its flue is clear, and forcing repeated attempts is the wrong response to that. Book a Gas Safe engineer and make sure your CO alarm is working.

Why does my ecoTEC plus manual not list F.33?

The ..6/5-5 plus, the pro, the ecoFIT and the ecoTEC sustain prove air flow from the fan's speed signal and report a problem as F.32. F.33 appears on the exclusive, the 48–64 kW plus and the turboMAX plus 837 and 637, which have a pressure switch or sensor.

Is it a fan fault or a flue fault?

Either, and Vaillant's list has the engineer look at the flue first. Only when the air route, the hose and the flue length check out does the switch or the fan get replaced.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?