Vaillant F.94 fault codewhat it means and how to fix it

Get it checkedBoilerecoTEC plus ..6/5-5 and its storage combis, ecoTEC exclusive (both editions). Not in the ecoTEC pro, ecoFIT, ecoTEC sustain, CS/1-5 or older tables.Last updated

The vortex and differential pressure sensors — the two that measure flow through the heat exchanger on an ecoTEC plus or exclusive — are returning values the board does not believe.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get a Gas Safe registered engineer to look at the Vaillant properly.

Get a Gas Safe registered engineer to look at your Vaillant F.94

We do not pass enquiries to a repair firm, so there is no form here. Find a Gas Safe registered engineer through the Gas Safe Register, and ask to see their registration card when they arrive — it is the register, not the van, that tells you they are qualified.

What F.94 means

The ecoTEC plus ..6/5-5 and exclusive measure water flow through the primary circuit with a vortex sensor and read the pressure drop across it with a differential pressure sensor. Together they let the board judge circulation directly rather than infer it from temperatures. F.94 is those readings failing plausibility: the plus prints "fault: vortex and differential pressure — sensors return implausible values; check cable harness, plug, sensors", and the exclusive adds the pump to the front of the list, "check: pump (function), cable harness, plug, sensors". The exclusive's addition is the useful clue.

If the pump is not moving water, both sensors report something the board considers impossible, so a pump fault can present as F.94 before it presents as anything else. The remaining causes are the sensors' wiring and the sensors themselves. F.94 is not on the pro, ecoFIT, ecoTEC sustain or 2022 CS/1-5 tables — the pro and ecoFIT judge circulation from the temperature spread and report it as F.23, F.24 or F.72, and the CS/1-5 has a family of F.32x pump codes for the same territory. It is an engineer's repair throughout.

What causes it

Causes of the Vaillant F.94 fault code, most common first
CauseWhat is actually happeningHow likely
Pump not circulatingFirst on the exclusive's list. A stalled or failing pump leaves no flow for the vortex sensor to read and no pressure drop for the differential sensor.Common
Sensor plug or harness faultVaillant's cable harness and plug. Two sensors, two leads, and a disturbed connector on either gives the code.Common
Vortex or differential pressure sensor failedThe sensor itself. Diagnosed by comparing its output with the other and with a known flow.Occasional
Air in the primary circuitAir passing the vortex sensor produces readings that jump about. Not on Vaillant's list by name, but a reason the pump check comes first.Occasional

Can you fix it yourself?

What it costs to fix

Typical repair cost

£80–£320

Time on site

1 hour

A plug or harness fault is a call-out of £80 to £150. A sensor is £120 to £200 fitted; a pump £250 to £320.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Parts you may need

We may earn a commission if you buy a part through one of these links. It does not change what you pay, and it does not affect which parts we list.

Central heating circulating pump

CH-PUMP-15-60£90–£180Plumbing merchant

Price checked 28 September 2026

Vaillant wiring harness (plug-and-cable set to a sensor or actuator)

£20–£65Authorised Vaillant parts distributor

Price checked 28 September 2026

Own this appliance and had this code? . Nothing is published until a person has read it.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?