Daikin C0 fault codewhat it means and how to fix it

Get it checkedHeat pumpDaikin Altherma heat pumps. Shown as C0 on older displays, C0-00 "Flow sensor/switch malfunction" on the 2018 Altherma LT split, and C0-00, C0-01 or C0-02 on Altherma 3 controllers.Last updated

Flow sensor malfunction: the sensor sees water moving 45 seconds after Daikin’s pump has stopped. Low pressure, air and an external pump running are on the list before the sensor itself.

Take care

Some of this is safe to check yourself, but the repair itself is not. If the fault comes back after one reset, stop resetting it and get an F-Gas certified heat pump engineer to look at the Daikin properly.

What C0 means

C0 looks like a broken sensor and often is not. Daikin’s table gives C0-00 as flow sensor malfunction and C0-01 and C0-02 as flow switch malfunction, and the service manual explains the trigger for the first: the water flow sensor detects water flow 45 seconds after the water pump has stopped. The unit stops and the reset is manual. Think about what that trigger means. The Altherma has switched its own pump off and expects the water to stand still; instead, the sensor says water is still moving.

Daikin’s checklist begins on the water side — check the water pressure, check the water flow, purge the water circuit — and then names the cause that catches installers out: check the water circuit for an external pump, because the detected flow may be caused by a pump that is not the Altherma’s. Underfloor heating manifolds, secondary hot water circulation and buffer arrangements all have pumps of their own, and one that keeps running when the heat pump has stopped will push water through the flow sensor and produce C0. Air is the other non-fault cause: a pocket of air moving through the sensor after the pump stops reads as flow, which is why purging is on the list and why the code follows recent work on the system. Only after those does Daikin reach the sensor’s electrical check and the hydro PCB.

For C0-01 and C0-02 the trigger is the equivalent on a flow switch — flow detected while the pump is not running — and C0-01 resets automatically. The owner’s contribution is context: what other pumps exist on the system, what work has been done recently, and whether the code coincides with underfloor or hot water circulation running.

What causes it

Causes of the Daikin C0 fault code, most common first
CauseWhat is actually happeningHow likely
An external pump moving water through the sensorDaikin’s fourth check and the one most often missed. An underfloor manifold pump or secondary circulation pump running after the Altherma stops produces flow the sensor faithfully reports.Common
Air in the water circuitDaikin’s third check. Air moving through the sensor after the pump stops reads as flow, and it follows any recent work on radiators or the cylinder.Common
Water pressure or flow too lowDaikin’s first two checks. A circuit short of pressure behaves oddly around the sensor, and the checks cost nothing.Occasional
Flow sensor or hydro PCB faultyThe last two items on Daikin’s list, reached after the water side and any external pump have been ruled out.Occasional

What to try yourself

  1. Read the system pressure gauge and note it. Water pressure is Daikin’s first check for this code.

  2. List the other pumps on your system — underfloor manifold, hot water circulation, buffer or boiler pumps — and notice whether any runs when the heat pump has stopped. That is Daikin’s named cause and it is the one only you can observe.

  3. Think about recent work. Air after a drain-down or radiator job is Daikin’s third check.

  4. Book your installer with the code and what you found. The sensor’s electrical check and the hydro PCB are theirs, and an external pump that needs interlocking with the heat pump is a wiring job.

    Do not purge the primary circuit yourself unless your installer has shown you how on your system. It may contain glycol, and the indoor unit carries mains.

Get an F-Gas certified heat pump engineer to look at your Daikin C0

We do not pass enquiries to a repair firm, so there is no form here. When you book an F-Gas certified heat pump engineer, tell them the make, the model and the exact code or message on the display, and ask whether they carry parts for this make — that is what turns one visit into a repair rather than a quote.

What it costs to fix

Typical repair cost

£90–£400

Time on site

15 minutes

An installer visit is typically £90 to £180 and a purge fits inside it. Interlocking an external pump is a modest wiring job; a replacement flow sensor or hydro PCB is where the range widens.

Typical UK prices including parts and labour, updated September 2026. Your quote may differ.

Own this appliance and had this code? . Nothing is published until a person has read it.

Common questions about Daikin C0

Is the sensor broken?

Possibly, but Daikin put it fifth on a six-item list. Before the sensor come water pressure, water flow, air, and an external pump moving water through it after the Altherma has stopped. A sensor that reports flow when there genuinely is flow is not faulty.

What is the difference between C0-00 and C0-01?

The device. C0-00 is the flow sensor, which measures how much water is moving; C0-01 and C0-02 are a flow switch, which only knows whether water is moving. Both trigger when flow is detected with the pump off, and Daikin publish C0-01 as resetting automatically.

Is this the same as 7H?

The opposite. 7H is too little flow when the pump is running. C0 is flow detected when the pump is stopped. Both involve the same sensor and the same water circuit, which is why air and pressure appear on both lists.

Written by

Andrew Pickett

Researcher and writer

Last updated

Technical review

Not reviewed by an engineer

No engineer has read this page. Severity follows what the manufacturer publishes, and we would rather tell you that than let a byline imply a sign-off.

What we check instead

Sources and how we verified this

We establish the facts from the sources below and then write the explanation ourselves. We do not copy manufacturer wording and we do not host their manuals.

  • Manufacturer technical and service documentation

This page has not been reviewed by an engineer, and we would rather tell you that than imply otherwise. The severity rating follows what the manufacturer publishes: where they say isolate the appliance and call someone, so do we.

Read our full verification process

Was this page helpful?